NVC Battens & Linear Lights in Pakistan
FMST lists 173 NVC battens & linear lights order codes in 7 families, from 11W to 70W, with protection up to IP40, as an Authorized Partner & Distributor in Lahore supplying projects across Pakistan.
— NVC International · British Engineered —
All 173 NVC battens & linear lights.
Tap a card for its order codes, ratings and features, and a WhatsApp quote. Search by order code, or use the family table and order-code index below.







NVC battens & linear lights by family.
All 7 families in this range with the power, colour temperatures and ratings printed in the NVC Lighting Catalogue 2026. A dash means the catalogue does not state it; WhatsApp 0306 4758850 for the datasheet.
| Family | Order codes | Power | Colour temperature | IP / IK | Catalogue |
|---|---|---|---|---|---|
| TEXAS PRO | 24 | 11W–58W | 3000K · 4000K · 6000K | IP20 · IK08 | p. 32 |
| RANGER | 6 | 18W–62W | 3000K · 4000K · 6000K | IP20 · IK08 | p. 36 |
| YALE PRO | 36 | 20W–58W | 4000K | IP40 · IK10 | p. 16 |
| DALLAS PRO | 32 | 16W–55W | 3000K · 4000K | IP20 | p. 20 |
| BROADWAY | 36 | 11W–50W | 4000K | IP20 | p. 24 |
| PHOENIX | 38 | 28W–70W | 4000K · 5000K | IP20 | p. 28 |
| TEXAS | 1 | — | — | — | — |
Order-code index: all 173 NVC battens & linear lights
| Order code | Version | Power (W) | Lumens (lm) | CCT (K) | Family |
|---|---|---|---|---|---|
| NTE4/11-20/830-40-60 | Standard | 11 / 14 / 17 / 20 | 1756 / 2180 / 2633 / 3047 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE4/11-20/M3L/830-40-60 | Standard | 11 / 14 / 17 / 20 | 1756 / 2180 / 2633 / 3047 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE4/18-33/830-40-60 | Standard | 18 / 23 / 28 / 33 | 2887 / 3625 / 4288 / 4991 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE4/18-33/M3L/830-40-60 | Standard | 18 / 23 / 28 / 33 | 2887 / 3625 / 4288 / 4991 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE5/18-32/830-40-60 | Standard | 18 / 23 / 27 / 32 | 2924 / 3747 / 4439 / 5187 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE5/18-32/M3L/830-40-60 | Standard | 18 / 23 / 27 / 32 | 2924 / 3747 / 4439 / 5187 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE5/29-52/830-40-60 | Standard | 29 / 37 / 45 / 52 | 4794 / 5923 / 7058 / 8132 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE5/29-52/M3L/830-40-60 | Standard | 29 / 37 / 45 / 52 | 4794 / 5923 / 7058 / 8132 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE6/21-38/830-40-60 | Standard | 21 / 27 / 32 / 38 | 3377 / 4270 / 5067 / 5925 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE6/21-38/M3L/830-40-60 | Standard | 21 / 27 / 32 / 38 | 3377 / 4270 / 5067 / 5925 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE6/32-58/830-40-60 | Standard | 32 / 40 / 50 / 58 | 5165 / 6388 / 7705 / 8827 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE6/32-58/M3L/830-40-60 | Standard | 32 / 40 / 50 / 58 | 5165 / 6388 / 7705 / 8827 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE4/11-20/DD/830-40-60 | Digital Dimming (DD) | 11 / 14 / 17 / 20 | 1756 / 2180 / 2633 / 3047 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE4/11-20/DD/M3L/830-40-60 | Digital Dimming (DD) | 11 / 14 / 17 / 20 | 1756 / 2180 / 2633 / 3047 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE4/18-33/DD/830-40-60 | Digital Dimming (DD) | 18 / 23 / 28 / 33 | 2887 / 3625 / 4288 / 4991 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE4/18-33/DD/M3L/830-40-60 | Digital Dimming (DD) | 18 / 23 / 28 / 33 | 2887 / 3625 / 4288 / 4991 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE5/18-32/DD/830-40-60 | Digital Dimming (DD) | 18 / 23 / 27 / 32 | 2924 / 3747 / 4439 / 5187 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE5/18-32/DD/M3L/830-40-60 | Digital Dimming (DD) | 18 / 23 / 27 / 32 | 2924 / 3747 / 4439 / 5187 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE5/29-52/DD/830-40-60 | Digital Dimming (DD) | 29 / 37 / 45 / 52 | 4794 / 5923 / 7058 / 8132 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE5/29-52/DD/M3L/830-40-60 | Digital Dimming (DD) | 29 / 37 / 45 / 52 | 4794 / 5923 / 7058 / 8132 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE6/21-38/DD/830-40-60 | Digital Dimming (DD) | 21 / 27 / 32 / 38 | 3377 / 4270 / 5067 / 5925 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE6/21-38/DD/M3L/830-40-60 | Digital Dimming (DD) | 21 / 27 / 32 / 38 | 3377 / 4270 / 5067 / 5925 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE6/32-58/DD/830-40-60 | Digital Dimming (DD) | 32 / 40 / 50 / 58 | 5165 / 6388 / 7705 / 8827 | 3000 / 4000 / 6000 | TEXAS PRO |
| NTE6/32-58/DD/M3L/830-40-60 | Digital Dimming (DD) | 32 / 40 / 50 / 58 | 5165 / 6388 / 7705 / 8827 | 3000 / 4000 / 6000 | TEXAS PRO |
| NRG4/18-34/830-40-60 | Standard | 18 / 24 / 28 / 34 | 2716 / 3629 / 4186 / 4999 | 3000 / 4000 / 6000 | RANGER |
| NRG4/18-34/M3L/830-40-60 | Standard | 18 / 24 / 28 / 34 | 2716 / 3629 / 4186 / 4999 | 3000 / 4000 / 6000 | RANGER |
| NRG5/29-52/830-40-60 | Standard | 29 / 37 / 44 / 52 | 4318 / 5501 / 6449 / 7352 | 3000 / 4000 / 6000 | RANGER |
| NRG5/29-52/M3L/830-40-60 | Standard | 29 / 37 / 44 / 52 | 4318 / 5501 / 6449 / 7352 | 3000 / 4000 / 6000 | RANGER |
| NRG6/31-62/830-40-60 | Standard | 31 / 42 / 52 / 62 | 4888 / 6317 / 7678 / 8695 | 3000 / 4000 / 6000 | RANGER |
| NRG6/32-61/M3L/830-40-60 | Standard | 31 / 42 / 52 / 62 | 4888 / 6317 / 7678 / 8695 | 3000 / 4000 / 6000 | RANGER |
| NYA/4/20-37/840 | Standard, including manual test emergency (M3L) | 20 / 25 / 30 / 35 | 2600 / 3244 / 3861 / 4455 | 4000 | YALE PRO |
| NYA/4/20-37/M3L/840 | Standard, including manual test emergency (M3L) | 20 / 25 / 30 / 35 | 2600 / 3244 / 3861 / 4455 | 4000 | YALE PRO |
| NYA/5/27-44/840 | Standard, including manual test emergency (M3L) | 27 / 33 / 38 / 43 | 3675 / 4401 / 5134 / 5710 | 4000 | YALE PRO |
| NYA/5/27-44/M3L/840 | Standard, including manual test emergency (M3L) | 27 / 33 / 38 / 43 | 3675 / 4401 / 5134 / 5710 | 4000 | YALE PRO |
| NYA/6/36-58/840 | Standard, including manual test emergency (M3L) | 37 / 46 / 49 / 58 | 5078 / 6211 / 6511 / 7648 | 4000 | YALE PRO |
| NYA/6/36-58/M3L/840 | Standard, including manual test emergency (M3L) | 37 / 46 / 49 / 58 | 5078 / 6211 / 6511 / 7648 | 4000 | YALE PRO |
| NYA/4/20/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 20 | 2600 | 4000 | YALE PRO |
| NYA/4/20/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 20 | 2600 | 4000 | YALE PRO |
| NYA/4/25/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 25 | 3244 | 4000 | YALE PRO |
| NYA/4/25/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 25 | 3244 | 4000 | YALE PRO |
| NYA/4/30/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 30 | 3861 | 4000 | YALE PRO |
| NYA/4/30/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 30 | 3861 | 4000 | YALE PRO |
| NYA/4/37/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 35 | 4455 | 4000 | YALE PRO |
| NYA/4/37/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 35 | 4455 | 4000 | YALE PRO |
| NYA/5/27/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 27 | 3673 | 4000 | YALE PRO |
| NYA/5/27/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 27 | 3673 | 4000 | YALE PRO |
| NYA/5/33/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 33 | 4401 | 4000 | YALE PRO |
| NYA/5/33/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 33 | 4401 | 4000 | YALE PRO |
| NYA/5/38/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 38 | 5134 | 4000 | YALE PRO |
| NYA/5/38/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 38 | 5134 | 4000 | YALE PRO |
| NYA/5/44/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 43 | 5710 | 4000 | YALE PRO |
| NYA/5/44/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 43 | 5710 | 4000 | YALE PRO |
| NYA/6/36/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 37 | 5078 | 4000 | YALE PRO |
| NYA/6/36/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 37 | 5078 | 4000 | YALE PRO |
| NYA/6/45/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 46 | 6211 | 4000 | YALE PRO |
| NYA/6/45/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 46 | 6211 | 4000 | YALE PRO |
| NYA/6/48/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 49 | 6511 | 4000 | YALE PRO |
| NYA/6/48/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 49 | 6511 | 4000 | YALE PRO |
| NYA/6/58/DD/840 | Digital Dimming (DD), including manual test emergency (M3L) | 58 | 7648 | 4000 | YALE PRO |
| NYA/6/58/DD/M3L/840 | Digital Dimming (DD), including manual test emergency (M3L) | 58 | 7648 | 4000 | YALE PRO |
| NYA/4/20-37/MW/840 | Microwave sensor (MW), including manual test emergency (M3L) | 20 / 25 / 30 / 35 | 2600 / 3244 / 3861 / 4455 | 4000 | YALE PRO |
| NYA/4/20-37/MW/M3L/840 | Microwave sensor (MW), including manual test emergency (M3L) | 20 / 25 / 30 / 35 | 2600 / 3244 / 3861 / 4455 | 4000 | YALE PRO |
| NYA/5/27-44/MW/840 | Microwave sensor (MW), including manual test emergency (M3L) | 27 / 33 / 38 / 43 | 3675 / 4401 / 5134 / 5710 | 4000 | YALE PRO |
| NYA/5/27-44/MW/M3L/840 | Microwave sensor (MW), including manual test emergency (M3L) | 27 / 33 / 38 / 43 | 3675 / 4401 / 5134 / 5710 | 4000 | YALE PRO |
| NYA/6/36-58/MW/840 | Microwave sensor (MW), including manual test emergency (M3L) | 37 / 46 / 49 / 58 | 5078 / 6211 / 6511 / 7648 | 4000 | YALE PRO |
| NYA/6/36-58/MW/M3L/840 | Microwave sensor (MW), including manual test emergency (M3L) | 37 / 46 / 49 / 58 | 5078 / 6211 / 6511 / 7648 | 4000 | YALE PRO |
| NDL/4/16-28/WH/DO/830 | Down-only with manual test emergency (M3L) | 16 / 20 / 23 / 27 | 2262 / 2786 / 3327 / 3799 | 3000 | DALLAS PRO |
| NDL/4/16-28/WH/DO/M3L/830 | Down-only with manual test emergency (M3L) | 16 / 20 / 23 / 27 | 2262 / 2786 / 3327 / 3799 | 3000 | DALLAS PRO |
| NDL/5/27-42/WH/DO/830 | Down-only with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3623 / 4436 / 4656 / 5403 | 3000 | DALLAS PRO |
| NDL/5/27-42/WH/DO/M3L/830 | Down-only with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3623 / 4436 / 4656 / 5403 | 3000 | DALLAS PRO |
| NDL/4/16-28/WH/DO/840 | Down-only with manual test emergency (M3L) | 16 / 20 / 23 / 27 | 2381 / 2933 / 3502 / 3999 | 4000 | DALLAS PRO |
| NDL/4/16-28/WH/DO/M3L/840 | Down-only with manual test emergency (M3L) | 16 / 20 / 23 / 27 | 2381 / 2933 / 3502 / 3999 | 4000 | DALLAS PRO |
| NDL/5/27-42/WH/DO/840 | Down-only with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3814 / 4669 / 4906 / 5687 | 4000 | DALLAS PRO |
| NDL/5/27-42/WH/DO/M3L/840 | Down-only with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3814 / 4669 / 4906 / 5687 | 4000 | DALLAS PRO |
| NDL/4/16-28/BK/DO/830 | Down-only with manual test emergency (M3L) | 16 / 20 / 23 / 27 | 2262 / 2786 / 3327 / 3799 | 3000 | DALLAS PRO |
| NDL/4/16-28/BK/DO/M3L/830 | Down-only with manual test emergency (M3L) | 16 / 20 / 23 / 27 | 2262 / 2786 / 3327 / 3799 | 3000 | DALLAS PRO |
| NDL/5/27-42/BK/DO/830 | Down-only with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3623 / 4436 / 4656 / 5403 | 3000 | DALLAS PRO |
| NDL/5/27-42/BK/DO/M3L/830 | Down-only with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3623 / 4436 / 4656 / 5403 | 3000 | DALLAS PRO |
| NDL/4/16-28/BK/DO/840 | Down-only with manual test emergency (M3L) | 16 / 20 / 23 / 27 | 2381 / 2933 / 3502 / 3999 | 4000 | DALLAS PRO |
| NDL/4/16-28/BK/DO/M3L/840 | Down-only with manual test emergency (M3L) | 16 / 20 / 23 / 27 | 2381 / 2933 / 3502 / 3999 | 4000 | DALLAS PRO |
| NDL/5/27-42/BK/DO/840 | Down-only with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3814 / 4669 / 4906 / 5687 | 4000 | DALLAS PRO |
| NDL/5/27-42/BK/DO/M3L/840 | Down-only with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3814 / 4669 / 4906 / 5687 | 4000 | DALLAS PRO |
| NDL/4/26-40/WH/BD/830 | Bi-directional with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3539 / 4284 / 4525 / 5224 | 3000 | DALLAS PRO |
| NDL/4/26-40/WH/BD/M3L/830 | Bi-directional with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3539 / 4284 / 4525 / 5224 | 3000 | DALLAS PRO |
| NDL/5/43-55/WH/BD/830 | Bi-directional with manual test emergency (M3L) | 43 / 47 / 51 / 55 | 5661 / 6440 / 6559 / 7153 | 3000 | DALLAS PRO |
| NDL/5/43-55/WH/BD/M3L/830 | Bi-directional with manual test emergency (M3L) | 43 / 47 / 51 / 55 | 5661 / 6440 / 6559 / 7153 | 3000 | DALLAS PRO |
| NDL/4/26-40/WH/BD/840 | Bi-directional with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3725 / 4509 / 4763 / 5499 | 4000 | DALLAS PRO |
| NDL/4/26-40/WH/BD/M3L/840 | Bi-directional with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3725 / 4509 / 4763 / 5499 | 4000 | DALLAS PRO |
| NDL/5/43-55/WH/BD/840 | Bi-directional with manual test emergency (M3L) | 43 / 47 / 51 / 55 | 5959 / 6779 / 7009 / 7529 | 4000 | DALLAS PRO |
| NDL/5/43-55/WH/BD/M3L/840 | Bi-directional with manual test emergency (M3L) | 43 / 47 / 51 / 55 | 5959 / 6779 / 7009 / 7529 | 4000 | DALLAS PRO |
| NDL/4/26-40/BK/BD/830 | Bi-directional with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3539 / 4284 / 4525 / 5224 | 3000 | DALLAS PRO |
| NDL/4/26-40/BK/BD/M3L/830 | Bi-directional with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3539 / 4284 / 4525 / 5224 | 3000 | DALLAS PRO |
| NDL/5/43-55/BK/BD/830 | Bi-directional with manual test emergency (M3L) | 43 / 47 / 51 / 55 | 5661 / 6440 / 6559 / 7153 | 3000 | DALLAS PRO |
| NDL/5/43-55/BK/BD/M3L/830 | Bi-directional with manual test emergency (M3L) | 43 / 47 / 51 / 55 | 5661 / 6440 / 6559 / 7153 | 3000 | DALLAS PRO |
| NDL/4/26-40/BK/BD/840 | Bi-directional with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3725 / 4509 / 4763 / 5499 | 4000 | DALLAS PRO |
| NDL/4/26-40/BK/BD/M3L/840 | Bi-directional with manual test emergency (M3L) | 26 / 32 / 34 / 40 | 3725 / 4509 / 4763 / 5499 | 4000 | DALLAS PRO |
| NDL/5/43-55/BK/BD/840 | Bi-directional with manual test emergency (M3L) | 43 / 47 / 51 / 55 | 5959 / 6779 / 7009 / 7529 | 4000 | DALLAS PRO |
| NDL/5/43-55/BK/BD/M3L/840 | Bi-directional with manual test emergency (M3L) | 43 / 47 / 51 / 55 | 5959 / 6779 / 7009 / 7529 | 4000 | DALLAS PRO |
| NBW/10/WH/OP1/840 | OP1, 90o light distribution - White body | 11 | 1645 | 4000 | BROADWAY |
| NBW/15/WH/OP1/840 | OP1, 90o light distribution - White body | 16 | 2419 | 4000 | BROADWAY |
| NBW/20/WH/OP1/840 | OP1, 90o light distribution - White body | 20 | 3182 | 4000 | BROADWAY |
| NBW/25/WH/OP1/840 | OP1, 90o light distribution - White body | 25 | 3933 | 4000 | BROADWAY |
| NBW/30/WH/OP1/840 | OP1, 90o light distribution - White body | 30 | 4637 | 4000 | BROADWAY |
| NBW/35/WH/OP1/840 | OP1, 90o light distribution - White body | 34 | 5377 | 4000 | BROADWAY |
| NBW/40/WH/OP1/840 | OP1, 90o light distribution - White body | 39 | 6038 | 4000 | BROADWAY |
| NBW/45/WH/OP1/840 | OP1, 90o light distribution - White body | 45 | 6703 | 4000 | BROADWAY |
| NBW/50/WH/OP1/840 | OP1, 90o light distribution - White body | 50 | 7375 | 4000 | BROADWAY |
| NBW/10/BK/OP1/840 | OP1, 90o light distribution - Black body | 11 | 1645 | 4000 | BROADWAY |
| NBW/15/BK/OP1/840 | OP1, 90o light distribution - Black body | 16 | 2419 | 4000 | BROADWAY |
| NBW/20/BK/OP1/840 | OP1, 90o light distribution - Black body | 20 | 3182 | 4000 | BROADWAY |
| NBW/25/BK/OP1/840 | OP1, 90o light distribution - Black body | 25 | 3933 | 4000 | BROADWAY |
| NBW/30/BK/OP1/840 | OP1, 90o light distribution - Black body | 30 | 4637 | 4000 | BROADWAY |
| NBW/35/BK/OP1/840 | OP1, 90o light distribution - Black body | 34 | 5377 | 4000 | BROADWAY |
| NBW/40/BK/OP1/840 | OP1, 90o light distribution - Black body | 39 | 6038 | 4000 | BROADWAY |
| NBW/45/BK/OP1/840 | OP1, 90o light distribution - Black body | 45 | 6703 | 4000 | BROADWAY |
| NBW/50/BK/OP1/840 | OP1, 90o light distribution - Black body | 50 | 7375 | 4000 | BROADWAY |
| NBW/10/WH/OP2/840 | OP2, 60o light distribution - White body | 11 | 1652 | 4000 | BROADWAY |
| NBW/15/WH/OP2/840 | OP2, 60o light distribution - White body | 16 | 2461 | 4000 | BROADWAY |
| NBW/20/WH/OP2/840 | OP2, 60o light distribution - White body | 20 | 3304 | 4000 | BROADWAY |
| NBW/25/WH/OP2/840 | OP2, 60o light distribution - White body | 25 | 4033 | 4000 | BROADWAY |
| NBW/30/WH/OP2/840 | OP2, 60o light distribution - White body | 30 | 4803 | 4000 | BROADWAY |
| NBW/35/WH/OP2/840 | OP2, 60o light distribution - White body | 34 | 5562 | 4000 | BROADWAY |
| NBW/40/WH/OP2/840 | OP2, 60o light distribution - White body | 39 | 6274 | 4000 | BROADWAY |
| NBW/45/WH/OP2/840 | OP2, 60o light distribution - White body | 45 | 7047 | 4000 | BROADWAY |
| NBW/50/WH/OP2/840 | OP2, 60o light distribution - White body | 50 | 7812 | 4000 | BROADWAY |
| NBW/10/BK/OP2/840 | OP2, 60o light distribution - Black body | 11 | 1652 | 4000 | BROADWAY |
| NBW/15/BK/OP2/840 | OP2, 60o light distribution - Black body | 16 | 2461 | 4000 | BROADWAY |
| NBW/20/BK/OP2/840 | OP2, 60o light distribution - Black body | 20 | 3304 | 4000 | BROADWAY |
| NBW/25/BK/OP2/840 | OP2, 60o light distribution - Black body | 25 | 4033 | 4000 | BROADWAY |
| NBW/30/BK/OP2/840 | OP2, 60o light distribution - Black body | 30 | 4803 | 4000 | BROADWAY |
| NBW/35/BK/OP2/840 | OP2, 60o light distribution - Black body | 34 | 5562 | 4000 | BROADWAY |
| NBW/40/BK/OP2/840 | OP2, 60o light distribution - Black body | 39 | 6274 | 4000 | BROADWAY |
| NBW/45/BK/OP2/840 | OP2, 60o light distribution - Black body | 45 | 7047 | 4000 | BROADWAY |
| NBW/50/BK/OP2/840 | OP2, 60o light distribution - Black body | 50 | 7812 | 4000 | BROADWAY |
| NPH30/LED/840 | Standard, inluding manual test emergency (M3L) | 28 | 4308 | 4000 | PHOENIX |
| NPH30/LED/M3L/840 | Standard, inluding manual test emergency (M3L) | 28 | 4308 | 4000 | PHOENIX |
| NPH40/LED/840 | Standard, inluding manual test emergency (M3L) | 36 | 5470 | 4000 | PHOENIX |
| NPH40/LED/M3L/840 | Standard, inluding manual test emergency (M3L) | 36 | 5470 | 4000 | PHOENIX |
| NPH50/LED/840 | Standard, inluding manual test emergency (M3L) | 48 | 7008 | 4000 | PHOENIX |
| NPH50/LED/M3L/840 | Standard, inluding manual test emergency (M3L) | 48 | 7008 | 4000 | PHOENIX |
| NPH65/LED/840 | Standard, inluding manual test emergency (M3L) | 62 | 9630 | 4000 | PHOENIX |
| NPH65/LED/M3L/840 | Standard, inluding manual test emergency (M3L) | 62 | 9630 | 4000 | PHOENIX |
| NPH75/LED/840 | Standard, inluding manual test emergency (M3L) | 70 | 10128 | 4000 | PHOENIX |
| NPH75/LED/M3L/840 | Standard, inluding manual test emergency (M3L) | 70 | 10128 | 4000 | PHOENIX |
| NPH30/LED/850 | Standard, inluding manual test emergency (M3L) | 29 | 4382 | 5000 | PHOENIX |
| NPH30/LED/M3L/850 | Standard, inluding manual test emergency (M3L) | 29 | 4382 | 5000 | PHOENIX |
| NPH40/LED/850 | Standard, inluding manual test emergency (M3L) | 37 | 5633 | 5000 | PHOENIX |
| NPH40/LED/M3L/850 | Standard, inluding manual test emergency (M3L) | 37 | 5633 | 5000 | PHOENIX |
| NPH50/LED/850 | Standard, inluding manual test emergency (M3L) | 48 | 7186 | 5000 | PHOENIX |
| NPH50/LED/M3L/850 | Standard, inluding manual test emergency (M3L) | 48 | 7186 | 5000 | PHOENIX |
| NPH65/LED/850 | Standard, inluding manual test emergency (M3L) | 63 | 9710 | 5000 | PHOENIX |
| NPH65/LED/M3L/850 | Standard, inluding manual test emergency (M3L) | 63 | 9710 | 5000 | PHOENIX |
| NPH75/LED/850 | Standard, inluding manual test emergency (M3L) | 68 | 10536 | 5000 | PHOENIX |
| NPH75/LED/M3L/850 | Standard, inluding manual test emergency (M3L) | 68 | 10536 | 5000 | PHOENIX |
| NPH30/LED/DD/840 | Digital Dimming (DD) including manual test emergency (M3L) | 28 | 4308 | 4000 | PHOENIX |
| NPH30/LED/DD/M3L/840 | Digital Dimming (DD) including manual test emergency (M3L) | 28 | 4308 | 4000 | PHOENIX |
| NPH40/LED/DD/840 | Digital Dimming (DD) including manual test emergency (M3L) | 36 | 5470 | 4000 | PHOENIX |
| NPH40/LED/DD/M3L/840 | Digital Dimming (DD) including manual test emergency (M3L) | 36 | 5470 | 4000 | PHOENIX |
| NPH50/LED/DD/840 | Digital Dimming (DD) including manual test emergency (M3L) | 48 | 7008 | 4000 | PHOENIX |
| NPH50/LED/DD/M3L/840 | Digital Dimming (DD) including manual test emergency (M3L) | 48 | 7008 | 4000 | PHOENIX |
| NPH65/LED/DD/840 | Digital Dimming (DD) including manual test emergency (M3L) | 62 | 9630 | 4000 | PHOENIX |
| NPH65/LED/DD/M3L/840 | Digital Dimming (DD) including manual test emergency (M3L) | 62 | 9630 | 4000 | PHOENIX |
| NPH75/LED/DD/840 | Digital Dimming (DD) including manual test emergency (M3L) | 70 | 10128 | 4000 | PHOENIX |
| NPH75/LED/DD/M3L/840 | Digital Dimming (DD) including manual test emergency (M3L) | 70 | 10128 | 4000 | PHOENIX |
| NPH30/LED/DD/850 | Digital Dimming (DD) including manual test emergency (M3L) | 29 | 4382 | 5000 | PHOENIX |
| NPH30/LED/DD/M3L/850 | Digital Dimming (DD) including manual test emergency (M3L) | 29 | 4382 | 5000 | PHOENIX |
| NPH40/LED/DD/850 | Digital Dimming (DD) including manual test emergency (M3L) | 37 | 5633 | 5000 | PHOENIX |
| NPH40/LED/DD/M3L/850 | Digital Dimming (DD) including manual test emergency (M3L) | 37 | 5633 | 5000 | PHOENIX |
| NPH50/LED/DD/850 | Digital Dimming (DD) including manual test emergency (M3L) | 48 | 7186 | 5000 | PHOENIX |
| NPH65/LED/DD/850 | Digital Dimming (DD) including manual test emergency (M3L) | 48 | 7186 | 5000 | PHOENIX |
| NPH65/LED/DD/M3L/850 | Digital Dimming (DD) including manual test emergency (M3L) | 63 | 9710 | 5000 | PHOENIX |
| NPH75/LED/DD/850 | Digital Dimming (DD) including manual test emergency (M3L) | 68 | 10536 | 5000 | PHOENIX |
| — | TEXAS | — | — | — | TEXAS |
Technical documentation.
NVC battens & linear lights.
Delivered by FMST.
Project quotes, datasheets, IES files, DIALux lighting design — one source for the full NVC UK range in Pakistan.
The same products from other brands we supply
All LED tube lights and battens from 14 brands
Compare the same product across the lighting brands FMST supplies in Lahore and across Pakistan.
NVC battens & linear lights: your questions.
What is the price of NVC battens & linear lights in Pakistan?
FMST quotes NVC battens & linear lights on request, because the rate depends on the model, wattage and quantity and changes with the market. WhatsApp 0306 4758850 with the order code (for example NTE4/11-20/830-40-60) and you get today's rate the same working day; project and bulk orders get wholesale rates.
Which NVC battens & linear lights does FMST supply?
TEXAS PRO (24 order codes, 11W–58W), RANGER (6 order codes, 18W–62W), YALE PRO (36 order codes, 20W–58W), DALLAS PRO (32 order codes, 16W–55W), BROADWAY (36 order codes, 11W–50W), PHOENIX (38 order codes, 28W–70W) and TEXAS. The order-code index on this page lists every version.
What wattage and lumen output do NVC battens & linear lights have?
Across the order codes on this page, power runs from 11W to 70W and light output from 1,645 lm to 10,536 lm, at up to 168 luminaire lumens per circuit watt, as printed in the NVC Lighting Catalogue 2026. Many NVC fittings are power selectable: one fitting covers several wattages, set on site.
What is the IP rating of NVC battens & linear lights?
TEXAS PRO and RANGER are IP20 and IK08; YALE PRO is IP40 and IK10; DALLAS PRO, BROADWAY and PHOENIX are IP20. The first IP digit is protection against dust and the second against water; IK is impact resistance, IK10 being the highest.
Which colour temperatures do NVC battens & linear lights come in?
3000K, 4000K, 6000K for TEXAS PRO and RANGER; 4000K for YALE PRO and BROADWAY; 3000K, 4000K for DALLAS PRO; 4000K, 5000K for PHOENIX. As a guide, 3000K is warm white, 4000K cool white and 5000K–6500K daylight.
Are NVC battens & linear lights dimmable?
TEXAS PRO (Digital Dimming), YALE PRO (Digital Dimming) and PHOENIX (Digital Dimming) have dimmable order codes in the catalogue; the order-code index shows which. Ask FMST on WhatsApp 0306 4758850 which control gear suits your dimmer or DALI system.
Do NVC battens & linear lights come with emergency backup?
Yes for TEXAS PRO, RANGER, YALE PRO, DALLAS PRO and PHOENIX: the catalogue lists emergency versions (M3L, M3 Lithium) that keep the light on from a battery during a power cut. M3 means 3 hours; ST is self-test.
How long do NVC battens & linear lights last?
The catalogue rates TEXAS PRO, YALE PRO, DALLAS PRO, BROADWAY and PHOENIX at L80 100,000 hours; RANGER at L70 50,000 hours. L80 means at least 80% of the original light output remains at that point.
Where are NVC battens & linear lights used?
TEXAS PRO: Suitable for a wide range of commercial and residential applications; Back and front-of-house uses include storerooms, corridors, offices and assembly areas in light industrial and commercial premises. RANGER: Suitable for a wide range of commercial and residential applications; Back-of-house uses include storerooms, corridors and assembly areas in light industrial and commercial premises. YALE PRO: Corridors and circulation areas in schools, colleges and hospitals; Classrooms; Hospital wards; Communal areas in public buildings. DALLAS PRO: Corridors and communal areas in offices, schools and public buildings; The suspended version is a great solution for spaces with high or sloping ceilings. BROADWAY: Server racks in a data hall; Aisles in a retail store.
Is FMST an Authorized Partner & Distributor of NVC, and do you deliver outside Lahore?
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor for NVC in Lahore, supplying genuine NVC lighting to contractors, developers, wholesalers and retail buyers across Pakistan, with nationwide delivery. WhatsApp 0306 4758850 with your list and city.





















