| Family | Order codes | Power | Colour temperature | IP / IK | Catalogue |
|---|---|---|---|---|---|
| GREENLAND PRO | 26 | 6W–77W | 2700K · 4000K · 6000K | IP66 · IK10 | p. 80 |
| GREENLAND CLASSIC | 43 | 10W–97W | 4000K · 5000K | IP66 · IK10 | p. 84 |
| COLUMBUS | 12 | 15W–71W | 4000K | IP65 · IK10 | p. 86 |
| CLEVELAND | 12 | 24W–74W | 4000K | IP65 · IK10 | p. 87 |
Order-code index: all 93 NVC waterproof & non-corrosive lights
| Order code | Version | Power (W) | Lumens (lm) | CCT (K) | Family |
|---|---|---|---|---|---|
| NGN2/8-14/840 | Standard, including manual test emergency (M3L) | 9 / 11 / 13 / 15 | 1256 / 1558 / 1838 / 2127 | 4000 | GREENLAND PRO |
| NGN4/23-40/840 | Standard, including manual test emergency (M3L) | 24 / 30 / 36 / 42 | 4064 / 5022 / 6025 / 6925 | 4000 | GREENLAND PRO |
| NGN4/23-40/M3L/840 | Standard, including manual test emergency (M3L) | 24 / 30 / 36 / 42 | 4064 / 5022 / 6025 / 6925 | 4000 | GREENLAND PRO |
| NGN5/34-60/840 | Standard, including manual test emergency (M3L) | 36 / 45 / 54 / 63 | 6021 / 7463 / 8906 / 10367 | 4000 | GREENLAND PRO |
| NGN5/34-60/M3L/840 | Standard, including manual test emergency (M3L) | 36 / 45 / 54 / 63 | 6021 / 7463 / 8906 / 10367 | 4000 | GREENLAND PRO |
| NGN6/52-74/840 | Standard, including manual test emergency (M3L) | 53 / 61 / 69 / 77 | 8726 / 9937 / 11092 / 12244 | 4000 | GREENLAND PRO |
| NGN6/52-74/M3L/840 | Standard, including manual test emergency (M3L) | 53 / 61 / 69 / 77 | 8726 / 9937 / 11092 / 12244 | 4000 | GREENLAND PRO |
| NGN4/23-40/DD/840 | Digital Dimming (DD) including manual test emergency (M3L) | 24 / 30 / 36 / 42 | 4064 / 5022 / 6025 / 6925 | 4000 | GREENLAND PRO |
| NGN4/23-40/DD/M3L/840 | Digital Dimming (DD) including manual test emergency (M3L) | 24 / 30 / 36 / 42 | 4064 / 5022 / 6025 / 6925 | 4000 | GREENLAND PRO |
| NGN5/34-60/DD/840 | Digital Dimming (DD) including manual test emergency (M3L) | 36 / 45 / 54 / 63 | 6021 / 7463 / 8906 / 10367 | 4000 | GREENLAND PRO |
| NGN5/34-60/DD/M3L/840 | Digital Dimming (DD) including manual test emergency (M3L) | 36 / 45 / 54 / 63 | 6021 / 7463 / 8906 / 10367 | 4000 | GREENLAND PRO |
| NGN6/52-74/DD/840 | Digital Dimming (DD) including manual test emergency (M3L) | 53 / 61 / 69 / 77 | 8726 / 9937 / 11092 / 12244 | 4000 | GREENLAND PRO |
| NGN6/52-74/DD/M3L/840 | Digital Dimming (DD) including manual test emergency (M3L) | 53 / 61 / 69 / 77 | 8726 / 9937 / 11092 / 12244 | 4000 | GREENLAND PRO |
| NGN2/6-12/827-40-60 | Standard CCT Selectable (2700K, 4000K & 6000K) including manual test emergency (M3L) | 6 / 8 / 10 / 12 | 780 / 1040 / 1300 / 1560 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN4/20-38/827-40-60 | Standard CCT Selectable (2700K, 4000K & 6000K) including manual test emergency (M3L) | 20 / 26 / 32 / 38 | 3160 / 4134 / 5024 / 5890 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN4/20-38/M3L/827-40-60 | Standard CCT Selectable (2700K, 4000K & 6000K) including manual test emergency (M3L) | 20 / 26 / 32 / 38 | 3160 / 4134 / 5024 / 5890 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN5/27-48/827-40-60 | Standard CCT Selectable (2700K, 4000K & 6000K) including manual test emergency (M3L) | 27 / 34 / 41 / 48 | 4239 / 5270 / 6314 / 7392 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN5/27-48/M3L/827-40-60 | Standard CCT Selectable (2700K, 4000K & 6000K) including manual test emergency (M3L) | 27 / 34 / 41 / 48 | 4239 / 5270 / 6314 / 7392 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN6/34-60/827-40-60 | Standard CCT Selectable (2700K, 4000K & 6000K) including manual test emergency (M3L) | 34 / 42 / 51 / 60 | 5270 / 6426 / 7752 / 9000 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN6/34-60/M3L/827-40-60 | Standard CCT Selectable (2700K, 4000K & 6000K) including manual test emergency (M3L) | 34 / 42 / 51 / 60 | 5270 / 6426 / 7752 / 9000 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN4/20-38/DD/827-40-60 | Digital Dimming (DD) CCT Selectable (2700K, 4000K & 6000K) incl. manual test emergency (M3L) | 20 / 26 / 32 / 38 | 780 / 1040 / 1300 / 1560 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN4/20-38/DD/M3L/827-40-60 | Digital Dimming (DD) CCT Selectable (2700K, 4000K & 6000K) incl. manual test emergency (M3L) | 20 / 26 / 32 / 38 | 3160 / 4134 / 5024 / 5890 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN5/27-48/DD/827-40-60 | Digital Dimming (DD) CCT Selectable (2700K, 4000K & 6000K) incl. manual test emergency (M3L) | 27 / 34 / 41 / 48 | 3160 / 4134 / 5024 / 5890 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN5/27-48/DD/M3L/827-40-60 | Digital Dimming (DD) CCT Selectable (2700K, 4000K & 6000K) incl. manual test emergency (M3L) | 27 / 34 / 41 / 48 | 4239 / 5270 / 6314 / 7392 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN6/34-60/DD/827-40-60 | Digital Dimming (DD) CCT Selectable (2700K, 4000K & 6000K) incl. manual test emergency (M3L) | 34 / 42 / 51 / 60 | 4239 / 5270 / 6314 / 7392 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN6/34-60/DD/M3L/827-40-60 | Digital Dimming (DD) CCT Selectable (2700K, 4000K & 6000K) incl. manual test emergency (M3L) | 34 / 42 / 51 / 60 | 5270 / 6426 / 7752 / 9000 | 2700 / 4000 / 6000 | GREENLAND PRO |
| NGN1X2/840 | Standard and with manual test emergency (M3L) | 10 | 1140 | 4000 | GREENLAND CLASSIC |
| NGN1X4/840 | Standard and with manual test emergency (M3L) | 28 | 3400 | 4000 | GREENLAND CLASSIC |
| NGN1X4/M3L/840 | Standard and with manual test emergency (M3L) | 28 | 3400 | 4000 | GREENLAND CLASSIC |
| NGN1X5/840 | Standard and with manual test emergency (M3L) | 36 | 5012 | 4000 | GREENLAND CLASSIC |
| NGN1X5/M3L/840 | Standard and with manual test emergency (M3L) | 36 | 5012 | 4000 | GREENLAND CLASSIC |
| NGN1X6/840 | Standard and with manual test emergency (M3L) | 48 | 5900 | 4000 | GREENLAND CLASSIC |
| NGN1X6/M3L/840 | Standard and with manual test emergency (M3L) | 48 | 5900 | 4000 | GREENLAND CLASSIC |
| NGN2X2/840 | Standard and with manual test emergency (M3L) | 17 | 2128 | 4000 | GREENLAND CLASSIC |
| NGN2X2/M3L/840 | Standard and with manual test emergency (M3L) | 17 | 2128 | 4000 | GREENLAND CLASSIC |
| NGN2X4/840 | Standard and with manual test emergency (M3L) | 45 | 6370 | 4000 | GREENLAND CLASSIC |
| NGN2X4/M3L/840 | Standard and with manual test emergency (M3L) | 45 | 6370 | 4000 | GREENLAND CLASSIC |
| NGN2X5/840 | Standard and with manual test emergency (M3L) | 73 | 9865 | 4000 | GREENLAND CLASSIC |
| NGN2X5/M3L/840 | Standard and with manual test emergency (M3L) | 73 | 9865 | 4000 | GREENLAND CLASSIC |
| NGN2X6/840 | Standard and with manual test emergency (M3L) | 97 | 11652 | 4000 | GREENLAND CLASSIC |
| NGN2X6/M3L/840 | Standard and with manual test emergency (M3L) | 97 | 11652 | 4000 | GREENLAND CLASSIC |
| NGN1X4/850 | Standard and with manual test emergency (M3L) | 28 | 3485 | 5000 | GREENLAND CLASSIC |
| NGN1X4/M3L/850 | Standard and with manual test emergency (M3L) | 28 | 3485 | 5000 | GREENLAND CLASSIC |
| NGN1X5/850 | Standard and with manual test emergency (M3L) | 36 | 5138 | 5000 | GREENLAND CLASSIC |
| NGN1X5/M3L/850 | Standard and with manual test emergency (M3L) | 36 | 5138 | 5000 | GREENLAND CLASSIC |
| NGN2X4/850 | Standard and with manual test emergency (M3L) | 45 | 6530 | 5000 | GREENLAND CLASSIC |
| NGN2X4/M3L/850 | Standard and with manual test emergency (M3L) | 45 | 6530 | 5000 | GREENLAND CLASSIC |
| NGN2X5/850 | Standard and with manual test emergency (M3L) | 73 | 10112 | 5000 | GREENLAND CLASSIC |
| NGN2X5/M3L/850 | Standard and with manual test emergency (M3L) | 73 | 10112 | 5000 | GREENLAND CLASSIC |
| NGN1X4/MW/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 28 | 3400 | 4000 | GREENLAND CLASSIC |
| NGN1X4/MW/M3L/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 28 | 3400 | 4000 | GREENLAND CLASSIC |
| NGN1X5/MW/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 36 | 5012 | 4000 | GREENLAND CLASSIC |
| NGN1X5/MW/M3L/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 36 | 5012 | 4000 | GREENLAND CLASSIC |
| NGN1X6/MW/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 48 | 5900 | 4000 | GREENLAND CLASSIC |
| NGN1X6/MW/M3L/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 48 | 5900 | 4000 | GREENLAND CLASSIC |
| NGN2X4/MW/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 45 | 6370 | 4000 | GREENLAND CLASSIC |
| NGN2X4/MW/M3L/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 45 | 6370 | 4000 | GREENLAND CLASSIC |
| NGN2X5/MW/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 73 | 9865 | 4000 | GREENLAND CLASSIC |
| NGN2X5/MW/M3L/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 73 | 9865 | 4000 | GREENLAND CLASSIC |
| NGN2X6/MW/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 97 | 11652 | 4000 | GREENLAND CLASSIC |
| NGN2X6/MW/M3L/840 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 97 | 11652 | 4000 | GREENLAND CLASSIC |
| NGN1X4/MW/850 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 28 | 3485 | 5000 | GREENLAND CLASSIC |
| NGN1X4/MW/M3L/850 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 28 | 3485 | 5000 | GREENLAND CLASSIC |
| NGN1X5/MW/850 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 36 | 5138 | 5000 | GREENLAND CLASSIC |
| NGN1X5/MW/M3L/850 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 36 | 5138 | 5000 | GREENLAND CLASSIC |
| NGN2X4/MW/850 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 45 | 6530 | 5000 | GREENLAND CLASSIC |
| NGN2X4/MW/M3L/850 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 45 | 6530 | 5000 | GREENLAND CLASSIC |
| NGN2X5/MW/850 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 73 | 10112 | 5000 | GREENLAND CLASSIC |
| NGN2X5/MW/M3L/850 | Microwave sensor (MW) and MW with manual test emergency (M3L) | 73 | 10112 | 5000 | GREENLAND CLASSIC |
| NCB/4/15-26/840 | COLUMBUS | 15 / 19 / 22 / 26 | 2090 / 2545 / 2946 / 3567 | 4000 | COLUMBUS |
| NCB/4/15-26/M3L/840 | COLUMBUS | 15 / 19 / 22 / 26 | 2090 / 2545 / 2946 / 3567 | 4000 | COLUMBUS |
| NCB/4/22-40/840 | COLUMBUS | 22 / 28 / 34 / 40 | 3429 / 4204 / 4885 / 5557 | 4000 | COLUMBUS |
| NCB/4/22-40/M3L/840 | COLUMBUS | 22 / 28 / 34 / 40 | 3429 / 4204 / 4885 / 5557 | 4000 | COLUMBUS |
| NCB/5/20-36/840 | COLUMBUS | 20 / 25 / 30 / 34 | 2739 / 3329 / 3859 / 4755 | 4000 | COLUMBUS |
| NCB/5/20-36/M3L/840 | COLUMBUS | 20 / 25 / 30 / 34 | 2739 / 3329 / 3859 / 4755 | 4000 | COLUMBUS |
| NCB/5/30-52/840 | COLUMBUS | 30 / 38 / 45 / 52 | 4397 / 5260 / 6198 / 7945 | 4000 | COLUMBUS |
| NCB/5/30-52/M3L/840 | COLUMBUS | 30 / 38 / 45 / 52 | 4397 / 5260 / 6198 / 7945 | 4000 | COLUMBUS |
| NCB/6/27-47/840 | COLUMBUS | 27 / 33 / 40 / 47 | 3695 / 4398 / 5154 / 6281 | 4000 | COLUMBUS |
| NCB/6/27-47/M3L/840 | COLUMBUS | 27 / 33 / 40 / 47 | 3695 / 4398 / 5154 / 6281 | 4000 | COLUMBUS |
| NCB/6/25-71/840 | COLUMBUS | 25 / 31 / 38 / 44 / 51 / 57 / 64 / 71 | 4035 / 4705 / 5679 / 6502 / 7394 / 8070 / 8844 / 9566 | 4000 | COLUMBUS |
| NCB/6/25-71/M3L/840 | COLUMBUS | 25 / 31 / 38 / 44 / 51 / 57 / 64 / 71 | 4035 / 4705 / 5679 / 6502 / 7394 / 8070 / 8844 / 9566 | 4000 | COLUMBUS |
| NCV1X4/840 | CLEVELAND | 24 | 2915 | 4000 | CLEVELAND |
| NCV1X4/M3L/840 | CLEVELAND | 24 | 2915 | 4000 | CLEVELAND |
| NCV2X4/840 | CLEVELAND | 40 | 4845 | 4000 | CLEVELAND |
| NCV2X4/M3L/840 | CLEVELAND | 40 | 4845 | 4000 | CLEVELAND |
| NCV1X5/840 | CLEVELAND | 35 | 3935 | 4000 | CLEVELAND |
| NCV1X5/M3L/840 | CLEVELAND | 35 | 3935 | 4000 | CLEVELAND |
| NCV2X5/840 | CLEVELAND | 57 | 6615 | 4000 | CLEVELAND |
| NCV2X5/M3L/840 | CLEVELAND | 57 | 6615 | 4000 | CLEVELAND |
| NCV1X6/840 | CLEVELAND | 46 | 5380 | 4000 | CLEVELAND |
| NCV1X6/M3L/840 | CLEVELAND | 46 | 5380 | 4000 | CLEVELAND |
| NCV2X6/840 | CLEVELAND | 74 | 9194 | 4000 | CLEVELAND |
| NCV2X6/M3L/840 | CLEVELAND | 74 | 9194 | 4000 | CLEVELAND |
Technical documentation.
NVC waterproof & non-corrosive lights.
Delivered by FMST.
Project quotes, datasheets, IES files, DIALux lighting design — one source for the full NVC UK range in Pakistan.
Waterproof lights from other brands we supply
Compare the same product across the lighting brands FMST supplies in Lahore and across Pakistan.
NVC waterproof & non-corrosive lights: your questions.
What is the price of NVC waterproof & non-corrosive lights in Pakistan?
FMST quotes NVC waterproof & non-corrosive lights on request, because the rate depends on the model, wattage and quantity and changes with the market. WhatsApp 0306 4758850 with the order code (for example NGN2/8-14/840) and you get today's rate the same working day; project and bulk orders get wholesale rates.
Which NVC waterproof & non-corrosive lights does FMST supply?
GREENLAND PRO (26 order codes, 6W–77W), GREENLAND CLASSIC (43 order codes, 10W–97W), COLUMBUS (12 order codes, 15W–71W) and CLEVELAND (12 order codes, 24W–74W). The order-code index on this page lists every version.
What wattage and lumen output do NVC waterproof & non-corrosive lights have?
Across the order codes on this page, power runs from 6W to 97W and light output from 780 lm to 12,244 lm, at up to 169 luminaire lumens per circuit watt, as printed in the NVC Lighting Catalogue 2026. Many NVC fittings are power selectable: one fitting covers several wattages, set on site.
What is the IP rating of NVC waterproof & non-corrosive lights?
GREENLAND PRO and GREENLAND CLASSIC are IP66 and IK10; COLUMBUS and CLEVELAND are IP65 and IK10. The first IP digit is protection against dust and the second against water; IK is impact resistance, IK10 being the highest.
Which colour temperatures do NVC waterproof & non-corrosive lights come in?
2700K, 4000K, 6000K for GREENLAND PRO; 4000K, 5000K for GREENLAND CLASSIC; 4000K for COLUMBUS and CLEVELAND. As a guide, 3000K is warm white, 4000K cool white and 5000K–6500K daylight.
Do NVC waterproof & non-corrosive lights come with emergency backup?
Yes for GREENLAND PRO, GREENLAND CLASSIC and CLEVELAND: the catalogue lists emergency versions (M3L) that keep the light on from a battery during a power cut. M3 means 3 hours; ST is self-test.
How long do NVC waterproof & non-corrosive lights last?
The catalogue rates GREENLAND PRO and GREENLAND CLASSIC at L80 100,000 hours; COLUMBUS and CLEVELAND at L70 50,000 hours. L80 means at least 80% of the original light output remains at that point.
Where are NVC waterproof & non-corrosive lights used?
GREENLAND PRO: Factories, garages and workshops; Food preparation areas. GREENLAND CLASSIC: Factories, garages and workshops; Food preparation areas. COLUMBUS: Factories, garages and workshops; Food preparation areas. CLEVELAND: Factories, garages and workshops; Food preparation areas.
Is FMST an Authorized Partner & Distributor of NVC, and do you deliver outside Lahore?