Authorized Partner & Distributor
EARTH LEAKAGE · RCCB · RCBO · RH99M RELAY · iPF SURGE ARRESTERS

Schneider Electric RCCB, RCBO & SPD in Pakistan

FMST lists 4 families of Schneider Electric RCCBs, RCBOs, leakage relays and SPDs (Acti9 RCCB, iC60 RCBO, RH99M and Acti9 iPF) with 19 models exactly as a February 2026 Schneider Electric price list prints them. FMST is an Authorized Partner & Distributor of Schneider Electric in Lahore.

4
families
19
models as printed
6–100 A
rated current printed
10 kA
breaking capacity printed
Schneider Electric Acti9 RCCB
Acti9 RCCB
Schneider Electric iC60 RCBO
iC60 RCBO
Schneider Electric RH99M
RH99M
Schneider Electric Acti9 iPF
Acti9 iPF
Schneider Electric · RCCB, RCBO & SPD

Schneider Electric RCCB, RCBO & SPD, family by family.

Schneider Electric’s own photos, printed specifications and every model, with order codes where Schneider prints them. Tap a card for the full table.

Acti9 RCCBSchneider Electric Acti9 RCCB

Schneider Electric Acti9 RCCB

Residual current circuit breaker (RCCB), 2-pole and 4-pole

2P, 4P · 25–100 A · 30 mA, 300 mA

5 modelslisted by type
Quote
iC60 RCBOSchneider Electric iC60 RCBO

Schneider Electric Acti9 iC60 RCBO

Residual current breaker with overcurrent protection (RCBO), 1P+N

1P+N · 6–40 A · 30 mA

7 modelslisted by type
Quote
RH99MSchneider Electric RH99M

Schneider Electric RH99M Earth Leakage Relay & Toroids

Adjustable earth leakage relay with toroids, for MCCBs and ACBs

0.03-30 A (adjustable)

5 modelslisted by type
Quote
Acti9 iPFSchneider Electric Acti9 iPF

Schneider Electric Acti9 iPF Surge Protective Devices

DIN-rail surge protective device (SPD), 3P+N

3P+N

2 models2 order numbers
Quote

Schneider Electric RCCB, RCBO & SPD at a glance.

All 4 families on this page, with the values a February 2026 Schneider Electric price list prints. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.

FamilyModelsPolesRated currentSensitivityBreaking capacityStandardSource
Schneider Electric Acti9 RCCB52P, 4P25–100 A30 mA, 300 mA——p. 8
Schneider Electric Acti9 iC60 RCBO71P+N6–40 A30 mA10 kA—p. 9
Schneider Electric RH99M Earth Leakage Relay & Toroids5——0.03-30 A (adjustable)——p. 9
Schneider Electric Acti9 iPF Surge Protective Devices23P+N————p. 9

Every model, as printed.

The 19 rows of these families exactly as a February 2026 Schneider Electric price list prints them, column for column. Where a cell is misprinted, a short note under the table says so.

Schneider Electric Acti9 RCCB

Residual current circuit breaker (RCCB), 2-pole and 4-pole · 5 rows · a February 2026 Schneider Electric price list, p. 8

MODELPolesRating (In)Sensitivity
RCCB D.P2P25, 40 A30 mA, 300 mA
RCCB D.P2P63 A30 mA, 300 mA
RCCB F.P4P25, 40 A30 mA, 300 mA
RCCB F.P4P63 A30 mA, 300 mA
RCCB F.P4P80, 100 A30 mA, 300 mA

Each row prints both sensitivities (“30mA, 300mA Sensitivity”) without saying which order is which: state 30 mA or 300 mA when you order. No order codes and no AC or A type are printed.

Schneider Electric Acti9 iC60 RCBO

Residual current breaker with overcurrent protection (RCBO), 1P+N · 7 rows · a February 2026 Schneider Electric price list, p. 9

MODELRating (In)PolesBreaking capacitySensitivity
RCBO6 A1P+N10 kA30 mA
RCBO10 A1P+N10 kA30 mA
RCBO16 A1P+N10 kA30 mA
RCBO20 A1P+N10 kA30 mA
RCBO25 A1P+N10 kA30 mA
RCBO32 A1P+N10 kA30 mA
RCBO40 A1P+N10 kA30 mA

No order codes and no AC or A type are printed.

Schneider Electric RH99M Earth Leakage Relay & Toroids

Adjustable earth leakage relay with toroids, for MCCBs and ACBs · 5 rows · a February 2026 Schneider Electric price list, p. 9

MODELDescriptionRating
RH99MEarth leakage relay, without ToroidSensitivity: 0.03-30 A (0-4.5 S Adjustable)
TOROID dia. 50mmToroid, 50 mm diameter—
TOROID dia. 80mmToroid, 80 mm diameter—
TOROID dia. 120mmToroid, 120 mm diameter—
TOROID dia. 200mmToroid, 200 mm diameter—

The list notes that one shunt trip on the breaker is needed to complete the scheme. Toroids are printed by diameter only.

Schneider Electric Acti9 iPF Surge Protective Devices

DIN-rail surge protective device (SPD), 3P+N · 2 rows · a February 2026 Schneider Electric price list, p. 9

MODELReferencePoleskA (as printed)
iPF65A9L155863P+N65 kA
iPF40A9L156883P+N40 kA

The kA figure is printed without saying whether it is Imax or In.

Compare all brands

The same products from every circuit breaker brand FMST supplies as an Authorized Partner & Distributor, on one page each.

Schneider Electric RCCB, RCBO & SPD: your questions.

What is the price of Schneider Electric RCCBs, RCBOs, leakage relays and SPDs in Pakistan?

FMST quotes Schneider Electric RCCBs, RCBOs, leakage relays and SPDs on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code and FMST replies with the current rate.

Which Schneider Electric RCCBs, RCBOs, leakage relays and SPDs does FMST supply?

Acti9 RCCB (5 models), iC60 RCBO (7 models), RH99M (5 models) and Acti9 iPF (2 models): 4 families and 19 models, each row as a February 2026 Schneider Electric price list prints it.

What is the difference between an RCCB and an RCBO?

An RCCB (also called an ELCB) trips on earth leakage to protect people from electric shock, but gives no overload or short-circuit protection, so it is used with MCBs; an RCBO is an RCCB and an MCB in one device. Schneider Electric RCCBs here: Acti9 RCCB. RCBOs: iC60 RCBO. Earth-leakage relays, which trip a separate breaker: RH99M.

Which sensitivity (mA) should an RCCB have?

30 mA is the sensitivity used to protect people against electric shock; 100 mA and 300 mA protect installations against fire from leakage. As printed: Acti9 RCCB 30 mA, 300 mA; iC60 RCBO 30 mA; RH99M 0.03-30 A (adjustable).

Is FMST an Authorized Partner & Distributor of Schneider Electric in Pakistan?

Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of Schneider Electric in Lahore, supplying genuine Schneider Electric RCCBs, RCBOs, leakage relays and SPDs to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.

Need Schneider Electric RCCB, RCBO & SPD? Send the codes.

WhatsApp the order codes from this page, or your load list, and FMST quotes genuine Schneider Electric. Electrical desk: 0306 4758850. All Schneider Electric categories: Schneider Electric circuit breakers.