ABB MS116 / MS132 / MS165 Manual Motor Starters (MPCB)
Manual motor starter / motor protection circuit breaker
0.63–80 A · 0.25–45 kW · 25–100 kA
FMST lists 2 families of ABB motor protection devices (MS116 / MS132 / MS165 and TF / TA) with 41 models exactly as the January 2025 ABB price list prints them. FMST is an Authorized Partner & Distributor of ABB in Lahore.


ABB’s own photos, printed specifications and every order code. Tap a card for the full table.

Manual motor starter / motor protection circuit breaker
0.63–80 A · 0.25–45 kW · 25–100 kA

Thermal overload relay for 3-pole contactors
0.1–200 A
Try another word, or search every ABB product.
All 2 families on this page, with the values the January 2025 ABB price list prints. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.
| Family | Models | Setting range | Motor power | Breaking capacity | Standard | Source |
|---|---|---|---|---|---|---|
| ABB MS116 / MS132 / MS165 Manual Motor Starters (MPCB) | 24 | 0.63–80 A | 0.25–45 kW | 25–100 kA | — | p. 31 |
| ABB TF / TA Thermal Overload Relays | 17 | 0.1–200 A | — | — | — | p. 30 |
The 41 rows of these families exactly as the January 2025 ABB price list prints them, column for column. Where a cell is misprinted, a short note under the table says so.
Manual motor starter / motor protection circuit breaker · 24 rows · the January 2025 ABB price list, p. 31
| MODEL | Rated power kW @ 400 V AC-3 | Setting range (A) | Breaking capacity Ics @ 400 V |
|---|---|---|---|
| MS116-1.0 | 0.25 | 0.63 ~ 1.00 | 50 kA |
| MS116-1.6 | 0.55 | 1.00 ~ 1.60 | 50 kA |
| MS116-2.5 | 0.75 | 1.60 ~ 2.50 | 50 kA |
| MS116-4.0 | 1.5 | 2.50 ~ 4.00 | 50 kA |
| MS116-6.3 | 2.2 | 4.00 ~ 6.30 | 50 kA |
| MS116-10 | 4.0 | 6.30 ~ 10.0 | 50 kA |
| MS116-12 | 5.5 | 8.00 ~ 12.0 | 50 kA |
| MS116-16 | 7.5 | 10.0 ~ 16.0 | 50 kA |
| MS 132-1.0 | 0.25 | 0.63 ~ 1.00 | 100 kA |
| MS 132-1.6 | 0.55 | 1.00 ~ 1.60 | 100 kA |
| MS 132-2.5 | 0.75 | 1.60 ~ 2.50 | 100 kA |
| MS 132-4.0 | 1.5 | 2.50 ~4.00 | 100 kA |
| MS 132-6.3 | 2.2 | 4.00 ~ 6.30 | 100 kA |
| MS 132-10 | 4.0 | 6.30 ~ 10.0 | 100 kA |
| MS 132-12 | 5.5 | 8.00 ~ 12.0 | 100 kA |
| MS 132-16 | 7.5 | 10.0 ~ 16.0 | 100 kA |
| MS 132-20 | 7.5 | 16.0 ~ 20.0 | 100 kA |
| MS 132-25 | 11 | 20.0 ~25.0 | 50 kA |
| MS 132-32 | 15 | 25.0 ~32.0 | 25 kA |
| MS 165-42 | 22 | 30.0 ~ 42.0 | 50 kA |
| MS 165-54 | 22 | 40.0 ~ 54.0 | 30 kA |
| MS 165-65 | 30 | 52.0 ~ 65.0 | 30 kA |
| MS 165-73 | 37 | 62.0 ~ 73.0 | 30 kA |
| MS 165-80 | 45 | 70.0 ~ 80.0 | 30 kA |
MS 132-20 is printed with 7.5 kW, the same as MS 132-16.
Thermal overload relay for 3-pole contactors · 17 rows · the January 2025 ABB price list, p. 30
| MODEL | Ampere range (A) | For 3-pole contactors |
|---|---|---|
| TF 42 | 0.10 ~ 0.13, 0.13 ~ 0.17, 0.17 ~ 0.23, 0.23 ~ 0.31, 0.31 ~ 0.41, 0.41 ~ 0.55, 0.55 ~ 0.74, 0.74 ~ 1, 1 ~ 1.3, 1.3 ~ 1.7, 1.7 ~ 2.3, 2.3 ~3.1, 3.1 ~ 4.2, 4.2 ~ 5.7, 5.7 ~ 7.6, 7.6 ~ 10 | AF 09 ~ AF 38 |
| TF 42 | 10 ~ 13, 13 ~ 16, 16 ~20 | AF 09 ~ AF 38 |
| TF 42 | 20 ~24, 24 ~ 29, 29 ~ 35, 35 ~ 38 | AF 09 ~ AF 38 |
| TF 65 | 22 ~ 28, 25 ~ 33, 30 ~ 40 | AF 30 ~ AF 65 |
| TF 65 | 36 ~ 47, 44 ~ 53, 50 ~ 60 | AF 30 ~ AF 65 |
| TF 65 | 57 ~ 67 | AF 30 ~ AF 65 |
| TF 96 | 40 ~ 51, 48 ~ 60 | AF 80 ~ AF 96 |
| TF 96 | 57 ~ 68 | AF 80 ~ AF 96 |
| TF 96 | 65 ~ 78 | AF 80 ~ AF 96 |
| TF 96 | 75 ~ 87 | AF 80 ~ AF 96 |
| TF 96 | 84 ~ 96 | AF 80 ~ AF 96 |
| TF 140 | 66 ~ 90 | AF 116 ~ AF 146 |
| TF 140 | 80 ~ 110, 100 ~ 135, 110 ~ 142 | AF 116 ~ AF 146 |
| TA 200 DU | 80 ~ 110 | AF 190 ~ AF 205 |
| TA 200 DU | 100 ~ 135 | AF 190 ~ AF 205 |
| TA 200 DU | 110 ~ 150 | AF 190 ~ AF 205 |
| TA 200 DU | 130 ~ 175, 150 ~ 200 | AF 190 ~ AF 205 |
TF 65 and TF 96 carry an asterisk in the list with no footnote. A printed row can hold several setting ranges.
FMST quotes ABB motor protection devices on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example MS116-1.0 and TF 42) and FMST replies with the current rate.
MS116 / MS132 / MS165 (24 models) and TF / TA (17 models): 2 families and 41 models, each row as the January 2025 ABB price list prints it.
A motor protection circuit breaker (MPCB, or manual motor starter) combines short-circuit and adjustable overload protection for one motor; a thermal overload relay mounts on a contactor and opens it on overload; a DOL starter is a contactor and overload relay in an enclosure that starts a motor direct on line. As printed: MS116 / MS132 / MS165 0.63–80 A, 0.25–45 kW; TF / TA 0.1–200 A.
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of ABB in Lahore, supplying genuine ABB motor protection devices to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.
WhatsApp the order codes from this page, or your load list, and FMST quotes genuine ABB. Electrical desk: 0306 4758850. All ABB categories: ABB circuit breakers.