ABB FH200 RCCB
Residual current circuit breaker (RCCB / ELCB), type AC
2P, 4P · 25–63 A · 30mA / 300mA
FMST lists 2 families of ABB RCCBs, RCBOs and surge protectors (FH200 and OVR T2) with 8 models exactly as the January 2025 ABB price list prints them, plus the F200 and DS201 from FMST’s earlier cards. FMST is an Authorized Partner & Distributor of ABB in Lahore.




ABB’s own photos, printed specifications and every order code. Tap a card for the full table.

Residual current circuit breaker (RCCB / ELCB), type AC
2P, 4P · 25–63 A · 30mA / 300mA

Residual current circuit breaker (RCCB)
2P, 4P · 16-125A · 30mA life / 100-500mA fire

Residual current breaker with overcurrent protection (RCBO), 1P+N
1P+N · 6-40A · 10/30/100/300mA

Type 2 surge protective device (pluggable, DIN rail)
40–80 kA
Try another word, or search every ABB product.
All 4 families on this page, with the values the January 2025 ABB price list prints. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.
| Family | Models | Poles | Rated current | Sensitivity | Breaking capacity | Standard | Imax | Voltage | Source |
|---|---|---|---|---|---|---|---|---|---|
| ABB FH200 RCCB | 6 | 2P, 4P | 25–63 A | 30mA / 300mA | — | — | — | — | p. 10 |
| ABB F200 RCCB | — | 2P, 4P | 16-125A | 30mA life / 100-500mA fire | — | IEC 61008-1 | — | — | FMST card |
| ABB DS201 RCBO | — | 1P+N | 6-40A | 10/30/100/300mA | 6kA (10kA DS201 M) | — | — | — | FMST card |
| ABB OVR T2 SPD | 2 | — | — | — | — | IEC 61643-11 / EN 61643-11 | 40–80 kA | TT/TNS : 230/400 V, TT/TN-S: 230/400 V | p. 11 |
The 8 rows of these families exactly as the January 2025 ABB price list prints them, column for column. Where a cell is misprinted, a short note under the table says so.
Residual current circuit breaker (RCCB / ELCB), type AC · 6 rows · the January 2025 ABB price list, p. 10
| MODEL | Poles | Rated current | Sensitivity (as printed) | Type |
|---|---|---|---|---|
| FH202 AC - 25 | 2P | 25A | 30mA / 300mA | AC |
| FH202 AC - 40 | 2P | 40A | 30mA / 300mA | AC |
| FH202 AC - 63 | 2P | 63A | 30mA / 300mA | AC |
| FH204 AC - 25 | 4P | 25A | 30mA / 300mA | AC |
| FH204 AC - 40 | 4P | 40A | 30mA / 300mA | AC |
| FH204 AC - 63 | 4P | 63A | 30mA / 300mA | AC |
Each table prints one “30mA / 300mA” cell for all its codes; the list does not say which code is 30 mA and which is 300 mA. The heading is spelt “RESIDEUAL”, as printed.
Residual current circuit breaker (RCCB) · not in the January 2025 ABB price list · FMST’s earlier ABB card; not in the January 2025 ABB price list
ABB F200 residual current circuit breakers, as FMST’s earlier ABB card lists them. Not in the January 2025 ABB price list (which prints the FH200): ask FMST for the ratings in stock.
Residual current breaker with overcurrent protection (RCBO), 1P+N · not in the January 2025 ABB price list · FMST’s earlier ABB card; not in the January 2025 ABB price list
ABB DS201 RCBOs, as FMST’s earlier ABB card lists them. Not in the January 2025 ABB price list: ask FMST for the ratings in stock.
Type 2 surge protective device (pluggable, DIN rail) · 2 rows · the January 2025 ABB price list, p. 11
| MODEL | Description (as printed) | Type | Imax | Up | System | Standard |
|---|---|---|---|---|---|---|
| OVR T2 N3 40-275 P TS QS | FP SURGE ARRESTOR TYPE-2 40KA | T2 | 40 kA | 1,25 kV | TT/TNS : 230/400 V | IEC 61643-11 / EN 61643-11 |
| OVR T2 3N 80-275s P TS QS | FP SURGE ARRESTOR TYPE-2 40KA | T2 | 80 kA | 1,4 kV | TT/TN-S: 230/400 V | IEC 61643-11 / EN 61643-11 |
The table describes OVR T2 3N 80-275s P TS QS as “FP SURGE ARRESTOR TYPE-2 40KA”; its specification panel and code say 80 kA.
The same products from every circuit breaker brand FMST supplies as an Authorized Partner & Distributor, on one page each.
FMST quotes ABB RCCBs, RCBOs and surge protectors on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example FH202 AC - 25 and OVR T2 N3 40-275 P TS QS) and FMST replies with the current rate.
FH200 (6 models) and OVR T2 (2 models): 2 families and 8 models, each row as the January 2025 ABB price list prints it, plus the F200 and DS201 from FMST’s earlier ABB cards (not in that list).
An RCCB (also called an ELCB) trips on earth leakage to protect people from electric shock, but gives no overload or short-circuit protection, so it is used with MCBs; an RCBO is an RCCB and an MCB in one device. ABB RCCBs here: FH200. FMST’s earlier cards add the F200 and DS201.
30 mA is the sensitivity used to protect people against electric shock; 100 mA and 300 mA protect installations against fire from leakage. As printed: FH200 30mA / 300mA.
Imax is the largest surge current (8/20 µs wave) the device can discharge; Uc is the highest voltage it can stay connected to continuously. As printed: OVR T2 40–80 kA, TT/TNS : 230/400 V, TT/TN-S: 230/400 V.
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of ABB in Lahore, supplying genuine ABB RCCBs, RCBOs and surge protectors to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.
WhatsApp the order codes from this page, or your load list, and FMST quotes genuine ABB. Electrical desk: 0306 4758850. All ABB categories: ABB circuit breakers.