Hager ARC AFDD + MCB
Arc fault detection device combined with an MCB
1P+N · 6–40 A · 6–10 kA
FMST lists 3 families of Hager arc fault detection devices (AFDD) (ARC AFDD + MCB, ARF AFDD + RCBO and ARL RCBO + AFDD) with 27 models exactly as Hager Ireland’s catalogue prints them. FMST is an Authorized Partner & Distributor of Hager in Lahore.



Hager’s own photos, printed specifications and every order code. Tap a card for the full table.

Arc fault detection device combined with an MCB
1P+N · 6–40 A · 6–10 kA

Arc fault detection device combined with an RCBO (3 modules)
1P+N · 6–25 A · 30 mA

One-module RCBO with arc fault detection
1P+N · 6–32 A · 30 mA
Try another word, or search every Hager product.
All 3 families on this page, with the values Hager Ireland’s catalogue prints. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.
| Family | Models | Poles | Rated current | Curve | Sensitivity | Breaking capacity | Source |
|---|---|---|---|---|---|---|---|
| Hager ARC AFDD + MCB | 14 | 1P+N | 6–40 A | B & C | — | 6–10 kA | Online catalogue · Residential PDF p. 31; Commercial PDF p. 160; flyer p. 2 |
| Hager ARF AFDD + RCBO | 7 | 1P+N | 6–25 A | B & C | 30 mA | 6–10 kA | Online catalogue · Commercial PDF p. 160 |
| Hager ARL RCBO + AFDD 1-module | 6 | 1P+N | 6–32 A | B | 30 mA | 6 kA | Online catalogue |
The 27 rows of these families exactly as Hager Ireland’s catalogue prints them, column for column. Where a cell is misprinted, a short note under the table says so.
Arc fault detection device combined with an MCB · 14 rows · Hager Ireland online catalogue, accessed November 2026; specifications: Residential Distribution catalogue (2024), p. 31; Commercial Distribution catalogue (2024), p. 160; at-a-glance flyer, p. 2
| Model | Description | Poles | Rated current In | Curve | Icn (IEC 60898-1) | Modules |
|---|---|---|---|---|---|---|
| ARC506U | MCB with dangerous arc detection 1P+N 10kA B-6A 2M | 1P+N | 6 A | B | 10 kA | 2 |
| ARC510U | MCB with dangerous arc detection 1P+N 10kA B-10A 2M | 1P+N | 10 A | B | 10 kA | 2 |
| ARC516U | MCB with dangerous arc detection 1P+N 10kA B-16A 2M | 1P+N | 16 A | B | 10 kA | 2 |
| ARC520U | MCB with dangerous arc detection 1P+N 10kA B-20A 2M | 1P+N | 20 A | B | 10 kA | 2 |
| ARC525U | MCB with dangerous arc detection 1P+N 10kA B-25A 2M | 1P+N | 25 A | B | 10 kA | 2 |
| ARC532U | MCB with dangerous arc detection 1P+N 10kA B-32A 2M | 1P+N | 32 A | B | 10 kA | 2 |
| ARC540U | MCB with dangerous arc detection 1P+N 10kA B-40A 2M | 1P+N | 40 A | B | 10 kA | 2 |
| ARC560U | MCB with dangerous arc detection 1P+N 10kA C-10A 2M | 1P+N | 10 A | C | 10 kA | 2 |
| ARC566U | MCB with dangerous arc detection 1P+N 10kA C-16A 2M | 1P+N | 16 A | C | 10 kA | 2 |
| ARC570U | MCB with dangerous arc detection 1P+N 10kA C-20A 2M | 1P+N | 20 A | C | 10 kA | 2 |
| ARC575U | MCB with dangerous arc detection 1P+N 10kA C-25A 2M | 1P+N | 25 A | C | 10 kA | 2 |
| ARC582U | MCB with dangerous arc detection 1P+N 10kA C-32A 2M | 1P+N | 32 A | C | 10 kA | 2 |
| ARC590U | MCB with dangerous arc detection 1P+N 10kA C-40A 2M | 1P+N | 40 A | C | 10 kA | 2 |
| ARC910U | MCB with dangerous arc detection 1P+N 6kA B-10A 2M | 1P+N | 10 A | B | 6 kA | 2 |
Hager Ireland marks ARC910U as being phased out.
Arc fault detection device combined with an RCBO (3 modules) · 7 rows · Hager Ireland online catalogue, accessed November 2026; specifications: Commercial Distribution catalogue (2024), p. 160
| Model | Description | Poles | Rated current In | Curve | Sensitivity IΔn | RCD type | Icn (IEC 60898-1) | Modules |
|---|---|---|---|---|---|---|---|---|
| ARF510D | RCBO with dangerous arc detection 10A B curve 10kA Type A 30mA | 1P+N | 10 A | B | 30 mA | A | 10 kA | 3 |
| ARF525D | RCBO with dangerous arc detection 25A B curve 10kA Type A 30mA | 1P+N | 25 A | B | 30 mA | A | 10 kA | 3 |
| ARF560D | RCBO with dangerous arc detection 10A C curve 10kA Type A 30mA | 1P+N | 10 A | C | 30 mA | A | 10 kA | 3 |
| ARF566D | RCBO with dangerous arc detection 16A C curve 10kA Type A 30mA | 1P+N | 16 A | C | 30 mA | A | 10 kA | 3 |
| ARF570D | RCBO with dangerous arc detection 20A C curve 10kA Type A 30mA | 1P+N | 20 A | C | 30 mA | A | 10 kA | 3 |
| ARF906D | RCBO with dangerous arc detection 6A B curve 6kA Type A 30mA | 1P+N | 6 A | B | 30 mA | A | 6 kA | 3 |
| ARF910D | RCBO with dangerous arc detection 10A B curve 6kA Type A 30mA | 1P+N | 10 A | B | 30 mA | A | 6 kA | 3 |
One-module RCBO with arc fault detection · 6 rows · Hager Ireland online catalogue, accessed November 2026
| Model | Description | Poles | Rated current In | Curve | Sensitivity IΔn | RCD type | Icn (IEC 60898-1) | Modules |
|---|---|---|---|---|---|---|---|---|
| ARL906U | RCBO with dangerous arc detection 1M 6A B curve 6kA Type A 30mA LFL 1m | 1P+N | 6 A | B | 30 mA | A | 6 kA | 1 |
| ARL910U | RCBO with dangerous arc detection 1M 10A B curve 6kA Type A 30mA LFL 1m | 1P+N | 10 A | B | 30 mA | A | 6 kA | 1 |
| ARL916U | RCBO with dangerous arc detection 1M 16A B curve 6kA Type A 30mA LFL 1m | 1P+N | 16 A | B | 30 mA | A | 6 kA | 1 |
| ARL920U | RCBO with dangerous arc detection 1M 20A B curve 6kA Type A 30mA LFL 1m | 1P+N | 20 A | B | 30 mA | A | 6 kA | 1 |
| ARL925U | RCBO with dangerous arc detection 1M 25A B curve 6kA Type A 30mA LFL 1m | 1P+N | 25 A | B | 30 mA | A | 6 kA | 1 |
| ARL932U | RCBO with dangerous arc detection 1M 32A B curve 6kA Type A 30mA LFL 1m | 1P+N | 32 A | B | 30 mA | A | 6 kA | 1 |
FMST quotes Hager arc fault detection devices (AFDD) on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example ARC506U and ARF510D) and FMST replies with the current rate.
ARC AFDD + MCB (14 models), ARF AFDD + RCBO (7 models) and ARL RCBO + AFDD (6 models): 3 families and 27 models, each row as Hager Ireland’s catalogue prints it.
An arc fault detection device (AFDD, IEC 62606) trips when it detects the electrical signature of a dangerous arc, such as one from a damaged cable or a loose connection, which an MCB or RCCB does not look for. Hager lists: ARC AFDD + MCB (Arc fault detection device combined with an MCB, 6–40 A, 1P+N); ARF AFDD + RCBO (Arc fault detection device combined with an RCBO (3 modules), 6–25 A, 1P+N); ARL RCBO + AFDD (One-module RCBO with arc fault detection, 6–32 A, 1P+N).
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of Hager in Lahore, supplying genuine Hager arc fault detection devices (AFDD) to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.
WhatsApp the order codes from this page, or your load list, and FMST quotes genuine Hager. Electrical desk: 0306 4758850. All Hager categories: Hager circuit breakers.