Hager CDA / CEA / CFA RCCB Type A
Residual current circuit breaker, Type A
2P, 4P · 40–100 A · 30 mA, 100 mA, 300 mA
FMST lists 7 families of Hager RCCBs, RCBOs and earth leakage relays (RCCB Type A, RCCB Type B / B+, RCD Add-On Blocks, ADA / ADB / ADC RCBO, AD / AEA / AF / AFA RCBO, ADX / AFX RCBO 4-pole and HR Earth Leakage Relays) with 133 models exactly as Hager Ireland’s catalogue prints them. FMST is an Authorized Partner & Distributor of Hager in Lahore.




Hager’s own photos, printed specifications and every order code. Tap a card for the full table.

Residual current circuit breaker, Type A
2P, 4P · 40–100 A · 30 mA, 100 mA, 300 mA

Residual current circuit breaker, Type B / B+
2P, 4P · 25–63 A · 30 mA, 300 mA

Residual current add-on block for MCBs
3P · 63 A · 30 mA

RCBO (MCB + RCD), 30 mA Type A
1P, 1P+N · 6–45 A · 30 mA

RCBO 1P+N, 2 modules, 6 kA
1P+N · 6–40 A · 30 mA, 100 mA, 300 mA

Four-pole RCBO
4P · 16–40 A · 30 mA, 300 mA

Earth leakage relay with separate toroidal current transformer
Try another word, or search every Hager product.
All 7 families on this page, with the values Hager Ireland’s catalogue prints. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.
| Family | Models | Poles | Rated current | Sensitivity | Breaking capacity | Standard | Source |
|---|---|---|---|---|---|---|---|
| Hager CDA / CEA / CFA RCCB Type A | 27 | 2P, 4P | 40–100 A | 30 mA, 100 mA, 300 mA | — | EN61008-1 | Online catalogue · Commercial PDF pp. 152, 153; Residential PDF p. 29 |
| Hager CDB / CFB RCCB Type B / B+ | 10 | 2P, 4P | 25–63 A | 30 mA, 300 mA | 10kA | EN61008-1 | Online catalogue · Commercial PDF pp. 152, 153 |
| Hager RCD Add-On Blocks for MCBs | 1 | 3P | 63 A | 30 mA | — | BS EN 61009-1 Appendix G | Online catalogue · Commercial PDF pp. 145, 146 |
| Hager ADA / ADB / ADC RCBO 30mA Type A | 36 | 1P, 1P+N | 6–45 A | 30 mA | 6–10 kA | BS EN 61009-1, IEC 61009-1 | Online catalogue · Residential PDF pp. 29, 30; Commercial PDF p. 149 |
| Hager AD / AEA / AF / AFA RCBO 1P+N 6kA | 26 | 1P+N | 6–40 A | 30 mA, 100 mA, 300 mA | 6kA (IEC 60 898-1) | — | Online catalogue · Commercial PDF pp. 149, 150; Residential PDF p. 30 |
| Hager ADX / AFX RCBO 4-pole 10kA | 13 | 4P | 16–40 A | 30 mA, 300 mA | 10 kA | — | Online catalogue · Commercial PDF p. 151 |
| Hager HR Earth Leakage Relays & Toroids | 20 | — | — | — | — | IEC 60755, IEC 947-2 annex B, IEC 61543, IEC 61008-1 | Online catalogue · Commercial PDF p. 186 |
The 133 rows of these families exactly as Hager Ireland’s catalogue prints them, column for column. Where a cell is misprinted, a short note under the table says so.
Residual current circuit breaker, Type A · 27 rows · Hager Ireland online catalogue, accessed November 2026; specifications: Commercial Distribution catalogue (2024), pp. 152, 153; Residential Distribution catalogue (2024), p. 29 · accessories: Auxiliaries & Accessories
| Model | Description | Poles | Rated current In | Sensitivity IΔn | RCD type | Modules |
|---|---|---|---|---|---|---|
| CD283U | RCCB 2P 80A 30mA A | 2 | 80 A | 30 mA | A | 2 |
| CD285U | RCCB 2P 100A 30mA A | 2 | 100 A | 30 mA | A | 2 |
| CDA240U | RCCB 2P 40A 30mA A Class | 2 | 40 A | 30 mA | A | 2 |
| CDA263U | RCCB 2P 63A 30mA A Class | 2 | 63 A | 30 mA | A | 2 |
| CDA440U | RCCB 4P 40A 30mA A Class | 4 | 40 A | 30 mA | A | 4 |
| CDA463U | RCCB 4P 63A 30mA A Class | 4 | 63 A | 30 mA | A | 4 |
| CDA563D | RCCB 1P+N 63A 30mA A | 2 | 63 A | 30 mA | A | 2 |
| CDA684D | RCCB 3P+N 100A 30mA A | 4 | 100 A | 30 mA | A | 4 |
| CE240J | RCCB 2P 40A 100mA A Class | 2 | 40 A | 100 mA | A | 2 |
| CE440J | RCCB 4P 40A 100mA A Class | 4 | 40 A | 100 mA | A | 4 |
| CE463J | RCCB 4P 63A 100mA A Class | 4 | 63 A | 100 mA | A | 4 |
| CEA263U | RCCB 2P 63A 100mA A Class | 2 | 63 A | 100 mA | A | 2 |
| CEA440E | RCCB 4P 40A 100mA A Class | 4 | 40 A | 100 mA | A | 4 |
| CEA580W | RCCB 1P+N 80A 100mA A | 2 | 80 A | 100 mA | A | 2 |
| CEA680W | RCCB 3P+N 80A 100mA A | 4 | 80 A | 100 mA | A | 4 |
| CEA684W | RCCB 3P+N 100A 100mA A | 4 | 100 A | 100 mA | A | 4 |
| CF240J | RCCB 2P 40A 300mA A Class | 2 | 40 A | 300 mA | A | 2 |
| CF263J | RCCB 2P 63A 300mA A Class | 2 | 63 A | 300 mA | A | 2 |
| CF440J | RCCB 4P 40A 300mA A Class | 4 | 40 A | 300 mA | A | 4 |
| CF463J | RCCB 4P 63A 300mA A Class | 4 | 63 A | 300 mA | A | 4 |
| CFA240U | RCCB 2P 40A 300mA A Class | 2 | 40 A | 300 mA | A | 2 |
| CFA584U | RCCB 1P+N 100A 300mA A | 2 | 100 A | 300 mA | A | 2 |
| CFA684W | RCCB 3P+N 100A 300mA A | 4 | 100 A | 300 mA | A | 4 |
| CNA584W | RCCB 1P+N 100A 100mA A S | 2 | 100 A | 100 mA | A SEL | 2 |
| CNA684D | RCCB 3P+N 100A 100mA A S | 4 | 100 A | 100 mA | A SEL | 4 |
| CPA584J | RCCB 1P+N 100A 300mA A S | 2 | 100 A | 300 mA | A SEL | 2 |
| CPA684U | RCCB 3P+N 100A 300mA A S | 4 | 100 A | 300 mA | A SEL | 4 |
Residual current circuit breaker, Type B / B+ · 10 rows · Hager Ireland online catalogue, accessed November 2026; specifications: Commercial Distribution catalogue (2024), pp. 152, 153
| Model | Description | Poles | Rated current In | Sensitivity IΔn | RCD type | Modules |
|---|---|---|---|---|---|---|
| CDB525D | RCCB 1P+N 25A 30mA B+ | 2 | 25 A | 30 mA | B+ | 4 |
| CDB540E | RCCB 1P+N 40A 30mA B | 2 | 40 A | 30 mA | B | 4 |
| CDB540HP | RCCB 1P+N 40A 30mA B Heat Pump | 2 | 40 A | 30 mA | B | 4 |
| CDB625D | RCCB 3P+N 25A 30mA B+ | 4 | 25 A | 30 mA | B+ | 4 |
| CDB640D | RCCB 3P+N 40A 30mA B+ | 4 | 40 A | 30 mA | B+ | 4 |
| CDB640E | RCCB 3P+N 40A 30mA B | 4 | 40 A | 30 mA | B | 4 |
| CDB663D | RCCB 3P+N 63A 30mA B+ | 4 | 63 A | 30 mA | B+ | 4 |
| CDB663E | RCCB 3P+N 63A 30mA B | 4 | 63 A | 30 mA | B | 4 |
| CFB640D | RCCB 3P+N 40A 300mA B+ | 4 | 40 A | 300 mA | B+ | 4 |
| CFB663D | RCCB 3P+N 63A 300mA B+ | 4 | 63 A | 300 mA | B+ | 4 |
Residual current add-on block for MCBs · 1 row · Hager Ireland online catalogue, accessed November 2026; specifications: Commercial Distribution catalogue (2024), pp. 145, 146
| Model | Description | Poles | Rated current In | Sensitivity IΔn | Modules |
|---|---|---|---|---|---|
| BD163T | Earth leakage add-on-block 3P 63A 30mA A Class 1mod Electronic | 3 | 63 A | 30 mA | 1 |
RCBO (MCB + RCD), 30 mA Type A · 36 rows · Hager Ireland online catalogue, accessed November 2026; specifications: Residential Distribution catalogue (2024), pp. 29, 30; Commercial Distribution catalogue (2024), p. 149 · accessories: Auxiliaries & Accessories
| Model | Description | Poles | Rated current In | Curve | Sensitivity IΔn | RCD type | Icn (IEC 60898-1) | Modules |
|---|---|---|---|---|---|---|---|---|
| ADA306G | RCBO Electronic 1P 6kA B Curve - 6A, 30mA Type A(AC & Pulsating DC Sensitive)1M | 1P | 6 A | B | 30 mA | A | 6 kA | 1 |
| ADA326G | RCBO Electronic 1P 6kA B Curve - 25A, 30mA Type A 1M | 1P | 25 A | B | 30 mA | A | 6 kA | 1 |
| ADA506D | RCBO 1P+N 10kA B-6A 30mA A Class | 1P+N | 6 A | B | 30 mA | A | 10 kA | 2 |
| ADA510D | RCBO 1P+N 10kA B-10A 30mA A Class | 1P+N | 10 A | B | 30 mA | A | 10 kA | 2 |
| ADA516D | RCBO 1P+N 10kA B-16A 30mA A Class | 1P+N | 16 A | B | 30 mA | A | 10 kA | 2 |
| ADA520D | RCBO 1P+N 10kA B-20A 30mA A Class | 1P+N | 20 A | B | 30 mA | A | 10 kA | 2 |
| ADA525D | RCBO 1P+N 10kA B-25A 30mA A Class | 1P+N | 25 A | B | 30 mA | A | 10 kA | 2 |
| ADA532D | RCBO 1P+N 10kA B-32A 30mA A Class | 1P+N | 32 A | B | 30 mA | A | 10 kA | 2 |
| ADA556D | RCBO 1P+N 10kA C-6A 30mA A Class | 1P+N | 6 A | C | 30 mA | A | 10 kA | 2 |
| ADA560D | RCBO 1P+N 10kA C-10A 30mA A Class | 1P+N | 10 A | C | 30 mA | A | 10 kA | 2 |
| ADA566D | RCBO 1P+N 10kA C-16A 30mA A Class | 1P+N | 16 A | C | 30 mA | A | 10 kA | 2 |
| ADA575D | RCBO 1P+N 10kA C-25A 30mA A Class | 1P+N | 25 A | C | 30 mA | A | 10 kA | 2 |
| ADB406U | RCBO 1M 1P 10kA B-6A 30mA Type A | 1P | 6 A | B | 30 mA | A | 10 kA | 1 |
| ADB410U | RCBO 1M 1P 10kA B-10A 30mA Type A | 1P | 10 A | B | 30 mA | A | 10 kA | 1 |
| ADB416U | RCBO 1M 1P 10kA B-16A 30mA Type A | 1P | 16 A | B | 30 mA | A | 10 kA | 1 |
| ADB420U | RCBO 1M 1P 10kA B-20A 30mA Type A | 1P | 20 A | B | 30 mA | A | 10 kA | 1 |
| ADB425U | RCBO 1M 1P 10kA B-25A 30mA Type A | 1P | 25 A | B | 30 mA | A | 10 kA | 1 |
| ADB432U | RCBO 1M 1P 10kA B-32A 30mA Type A | 1P | 32 A | B | 30 mA | A | 10 kA | 1 |
| ADB440G | RCBO 1M 1P 6kA B-40A 30mA Type A | 1P | 40 A | B | 30 mA | A | 6 kA | 1 |
| ADB440U | RCBO 1M 1P 10kA B-40A 30mA Type A | 1P | 40 A | B | 30 mA | A | 10 kA | 1 |
| ADB445G | RCBO 1M 1P 6kA B-45A 30mA Type A | 1P | 45 A | B | 30 mA | A | 6 kA | 1 |
| ADB445U | RCBO 1M 1P 10kA B-45A 30mA Type A | 1P | 45 A | B | 30 mA | A | 10 kA | 1 |
| ADB506G | Bidirectional RCBO 1M 1P+N 6kA B-6A 30mA type A | 1P+N | 6 A | B | 30 mA | A | 6 kA | 1 |
| ADB510G | Bidirectional RCBO 1M 1P+N 6kA B-10A 30mA type A | 1P+N | 10 A | B | 30 mA | A | 6 kA | 1 |
| ADB516G | Bidirectional RCBO 1M 1P+N 6kA B-16A 30mA type A | 1P+N | 16 A | B | 30 mA | A | 6 kA | 1 |
| ADB520G | Bidirectional RCBO 1M 1P+N 6kA B-20A 30mA type A | 1P+N | 20 A | B | 30 mA | A | 6 kA | 1 |
| ADB525G | Bidirectional RCBO 1M 1P+N 6kA B-25A 30mA type A | 1P+N | 25 A | B | 30 mA | A | 6 kA | 1 |
| ADB532G | Bidirectional RCBO 1M 1P+N 6kA B-32A 30mA type A | 1P+N | 32 A | B | 30 mA | A | 6 kA | 1 |
| ADC406U | RCBO 1M 1P 10kA C-6A 30mA Type A | 1P | 6 A | C | 30 mA | A | 10 kA | 1 |
| ADC410U | RCBO 1M 1P 10kA C-10A 30mA Type A | 1P | 10 A | C | 30 mA | A | 10 kA | 1 |
| ADC416U | RCBO 1M 1P 10kA C-16A 30mA Type A | 1P | 16 A | C | 30 mA | A | 10 kA | 1 |
| ADC420U | RCBO 1M 1P 10kA C-20A 30mA Type A | 1P | 20 A | C | 30 mA | A | 10 kA | 1 |
| ADC425U | RCBO 1M 1P 10kA C-25A 30mA Type A | 1P | 25 A | C | 30 mA | A | 10 kA | 1 |
| ADC432U | RCBO 1M 1P 10kA C-32A 30mA Type A | 1P | 32 A | C | 30 mA | A | 10 kA | 1 |
| ADC440U | RCBO 1M 1P 10kA C-40A 30mA Type A | 1P | 40 A | C | 30 mA | A | 10 kA | 1 |
| ADC445U | RCBO 1M 1P 10kA C-45A 30mA Type A | 1P | 45 A | C | 30 mA | A | 10 kA | 1 |
RCBO 1P+N, 2 modules, 6 kA · 26 rows · Hager Ireland online catalogue, accessed November 2026; specifications: Commercial Distribution catalogue (2024), pp. 149, 150; Residential Distribution catalogue (2024), p. 30
| Model | Description | Poles | Rated current In | Curve | Sensitivity IΔn | RCD type | Icn (IEC 60898-1) | Modules |
|---|---|---|---|---|---|---|---|---|
| AD906J | RCBO 1P+N 6kA B-6A 30mA A Class | 1P+N | 6 A | B | 30 mA | A | 6 kA | 2 |
| AD910J | RCBO 1P+N 6kA B-10A 30mA A Class | 1P+N | 10 A | B | 30 mA | A | 6 kA | 2 |
| AD920J | RCBO 1P+N 6kA B-20A 30mA A Class | 1P+N | 20 A | B | 30 mA | A | 6 kA | 2 |
| AD925J | RCBO 1P+N 6kA B-25A 30mA A Class | 1P+N | 25 A | B | 30 mA | A | 6 kA | 2 |
| AD932J | RCBO 1P+N 6kA B-32A 30mA A Class | 1P+N | 32 A | B | 30 mA | A | 6 kA | 2 |
| AD940J | RCBO 1P+N 6kA B-40A 30mA A Class | 1P+N | 40 A | B | 30 mA | A | 6 kA | 2 |
| AD956J | RCBO 1P+N 6kA C-6A 30mA A Class | 1P+N | 6 A | C | 30 mA | A | 6 kA | 2 |
| AD960J | RCBO 1P+N 6kA C-10A 30mA A Class | 1P+N | 10 A | C | 30 mA | A | 6 kA | 2 |
| AD966J | RCBO 1P+N 6kA C-16A 30mA A Class | 1P+N | 16 A | C | 30 mA | A | 6 kA | 2 |
| AD970J | RCBO 1P+N 6kA C-20A 30mA A Class | 1P+N | 20 A | C | 30 mA | A | 6 kA | 2 |
| AD975J | RCBO 1P+N 6kA C-25A 30mA A Class | 1P+N | 25 A | C | 30 mA | A | 6 kA | 2 |
| AD982J | RCBO 1P+N 6kA C-32A 30mA A Class | 1P+N | 32 A | C | 30 mA | A | 6 kA | 2 |
| AD990J | RCBO 1P+N 6kA C-40A 30mA A Class | 1P+N | 40 A | C | 30 mA | A | 6 kA | 2 |
| ADS917D | RCBO 1P+N 6kA 127V B-16A 30mA A Class QC&QB | 1P+N | 16 A | B | 30 mA | A | 6 kA | 2 |
| AEA906T | RCBO 1P+N 6kA C-6A 100mA A | 1P+N | 6 A | C | 100 mA | A | 6 kA | 2 |
| AEA916T | RCBO 1P+N 6kA C-16A 100mA A | 1P+N | 16 A | C | 100 mA | A | 6 kA | 2 |
| AEA920T | RCBO 1P+N 6kA C-20A 100mA A | 1P+N | 20 A | C | 100 mA | A | 6 kA | 2 |
| AEA925T | RCBO 1P+N 6kA C-25A 100mA A | 1P+N | 25 A | C | 100 mA | A | 6 kA | 2 |
| AEA932T | RCBO 1P+N 6kA C-32A 100mA A | 1P+N | 32 A | C | 100 mA | A | 6 kA | 2 |
| AEA940T | RCBO 1P+N 6kA C-40A 100mA A | 1P+N | 40 A | C | 100 mA | A | 6 kA | 2 |
| AFA910H | RCBO 1P+N 6kA C-10A 300mA A Class | 1P+N | 10 A | C | 300 mA | A | 6 kA | 2 |
| AFA916H | RCBO 1P+N 6kA C-16A 300mA A Class | 1P+N | 16 A | C | 300 mA | A | 6 kA | 2 |
| AFA920H | RCBO 1P+N 6kA C-20A 300mA A Class | 1P+N | 20 A | C | 300 mA | A | 6 kA | 2 |
| AFA925H | RCBO 1P+N 6kA C-25A 300mA A Class | 1P+N | 25 A | C | 300 mA | A | 6 kA | 2 |
| AFA932H | RCBO 1P+N 6kA C-32A 300mA A Class | 1P+N | 32 A | C | 300 mA | A | 6 kA | 2 |
| AFA940H | RCBO 1P+N 6kA C-40A 300mA A Class | 1P+N | 40 A | C | 300 mA | A | 6 kA | 2 |
Four-pole RCBO · 13 rows · Hager Ireland online catalogue, accessed November 2026; specifications: Commercial Distribution catalogue (2024), p. 151
| Model | Description | Poles | Rated current In | Curve | Sensitivity IΔn | RCD type | Icn (IEC 60898-1) | Modules |
|---|---|---|---|---|---|---|---|---|
| ADX425D | RCBO 4P 10kA B-25A 30mA type A | 4P | 25 A | B | 30 mA | A | 10 kA | 4 |
| ADX475D | RCBO 4P 10kA C-25A 30mA type A | 4P | 25 A | C | 30 mA | A | 10 kA | 4 |
| ADX482D | RCBO 4P 10kA C-32A 30mA type A | 4P | 32 A | C | 30 mA | A | 10 kA | 4 |
| AFX416D | RCBO 4P 10kA B-16A 300mA type A | 4P | 16 A | B | 300 mA | A | 10 kA | 4 |
| AFX420D | RCBO 4P 10kA B-20A 300mA type A | 4P | 20 A | B | 300 mA | A | 10 kA | 4 |
| AFX425D | RCBO 4P 10kA B-25A 300mA type A | 4P | 25 A | B | 300 mA | A | 10 kA | 4 |
| AFX432D | RCBO 4P 10kA B-32A 300mA type A | 4P | 32 A | B | 300 mA | A | 10 kA | 4 |
| AFX440D | RCBO 4P 10kA B-40A 300mA type A | 4P | 40 A | B | 300 mA | A | 10 kA | 4 |
| AFX466D | RCBO 4P 10kA C-16A 300mA type A | 4P | 16 A | C | 300 mA | A | 10 kA | 4 |
| AFX470D | RCBO 4P 10kA C-20A 300mA type A | 4P | 20 A | C | 300 mA | A | 10 kA | 4 |
| AFX475D | RCBO 4P 10kA C-25A 300mA type A | 4P | 25 A | C | 300 mA | A | 10 kA | 4 |
| AFX482D | RCBO 4P 10kA C-32A 300mA type A | 4P | 32 A | C | 300 mA | A | 10 kA | 4 |
| AFX490D | RCBO 4P 10kA C-40A 300mA type A | 4P | 40 A | C | 300 mA | A | 10 kA | 4 |
Earth leakage relay with separate toroidal current transformer · 20 rows · Hager Ireland online catalogue, accessed November 2026; specifications: Commercial Distribution catalogue (2024), p. 186
| Model | Description | Setting / size | Power absorbed | Positive safety contact |
|---|---|---|---|---|
| HR500 | Earth leakage relays non adjustable | fixed IΔn: 0.03A, instantaneous tripping | 3VA | — |
| HR502 | Earth leakage relays non adjustable | — | 3VA | — |
| HR510 | Earth leakage relays adjustable | adjustable IΔn: 0,03-0,1-0,3-0,5-1-3-10A; adjustable delay: 0-0,1-0,3-0,4-0,5-1-3 s | 5VA | 1 C/O |
| HR520 | Earth leakage relays adjustable | adjustable IΔn: 0,03-0,1-0,3-0,5-1-3-10A; adjustable delay: 0-0,1-0,3-0,4-0,5-1-3-5 s | 5VA | 1 C/O |
| HR522 | Earth leakage relays adjustable | adjustable IΔn: 0,03-0,1-0,3-0,5-1-3-10A; adjustable delay: 0-0,1-0,2-0,25-0,3-0,4-0,5 s | 5VA | 1 C/O |
| HR523 | Earth leakage relays adjustable | adjustable IΔn: 0,5-1-3-5-10-20-30A; adjustable delay: 0-0,1-0,2-0,25-0,3-0,4-0,5 s | 5VA | 1 C/O |
| HR525 | Earth leakage relays adjustable | adjustable IΔn: 0,03-0,1-0,3-0,5-1-3-10A; adjustable delay: 0-0,1-0,3-0,4-0,5-1-3 s | 6VA | 1 C/O |
| HR534 | Earth leakage relays adjustable | adjustable IΔn: 0,03-0,1-0,3-0,5-1-3-10-30A; Instantaneous / sel / adjustable delay: 0-0,1-0,3-0,4-0,5-1-3 s | 6VA | 1 C/O |
| HR700 | Circular torroids | Internal Ø 30 mm | — | — |
| HR741 | Circular torroids | Internal Ø35 mm | — | — |
| HR742 | Circular torroids | Internal Ø70 mm | — | — |
| HR743 | Circular torroids | Internal Ø105 mm | — | — |
| HR744 | Circular torroids | Internal Ø140 mm | — | — |
| HR745 | Circular torroids | Internal Ø210 mm | — | — |
| HR822 | Open rectangular torroids | 80 x 80 mm | — | — |
| HR823 | Open rectangular torroids | 80 x 120 mm | — | — |
| HR824 | Open rectangular torroids | 80 x 160 mm | — | — |
| HR830 | Rectangular torroids | 75 x 175 mm | — | — |
| HR831 | Rectangular torroids | 115 x 305 mm | — | — |
| HR832 | Rectangular torroids | 150 x 350 mm | — | — |
The same products from every circuit breaker brand FMST supplies as an Authorized Partner & Distributor, on one page each.
FMST quotes Hager RCCBs, RCBOs and earth leakage relays on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example CD283U and CDB525D) and FMST replies with the current rate.
RCCB Type A (27 models), RCCB Type B / B+ (10 models), RCD Add-On Blocks (1 model), ADA / ADB / ADC RCBO (36 models), AD / AEA / AF / AFA RCBO (26 models), ADX / AFX RCBO 4-pole (13 models) and HR Earth Leakage Relays (20 models): 7 families and 133 models, each row as Hager Ireland’s catalogue prints it.
An RCCB (also called an ELCB) trips on earth leakage to protect people from electric shock, but gives no overload or short-circuit protection, so it is used with MCBs; an RCBO is an RCCB and an MCB in one device. Hager RCCBs here: RCCB Type A, RCCB Type B / B+ and RCD Add-On Blocks. RCBOs: ADA / ADB / ADC RCBO, AD / AEA / AF / AFA RCBO and ADX / AFX RCBO 4-pole. Earth-leakage relays, which trip a separate breaker: HR Earth Leakage Relays.
30 mA is the sensitivity used to protect people against electric shock; 100 mA and 300 mA protect installations against fire from leakage. As printed: RCCB Type A 30 mA, 100 mA, 300 mA; RCCB Type B / B+ 30 mA, 300 mA; RCD Add-On Blocks 30 mA; ADA / ADB / ADC RCBO 30 mA; AD / AEA / AF / AFA RCBO 30 mA, 100 mA, 300 mA; ADX / AFX RCBO 4-pole 30 mA, 300 mA.
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of Hager in Lahore, supplying genuine Hager RCCBs, RCBOs and earth leakage relays to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.
WhatsApp the order codes from this page, or your load list, and FMST quotes genuine Hager. Electrical desk: 0306 4758850. All Hager categories: Hager circuit breakers.