Himel HDM3 MCCB (Fixed Thermal-Magnetic)
Moulded case circuit breaker, fixed thermal-magnetic trip
3P, 4P · 16–1,600 A · 25–75 kA
FMST lists 6 families of Himel MCCBs (HDM3, HDM3S, HDM3E, HDM3V Battery, CDMNE and M6Z DC) with 146 models exactly as the May 2025 Himel price list prints them. FMST is an Authorized Partner & Distributor of Himel in Lahore.




Himel’s own photos, printed specifications and every order code. Tap a card for the full table.

Moulded case circuit breaker, fixed thermal-magnetic trip
3P, 4P · 16–1,600 A · 25–75 kA

Moulded case circuit breaker, adjustable thermal-magnetic trip
3P, 4P · 25–630 A · 35–50 kA

Moulded case circuit breaker with adjustable electronic trip unit (LSI up to 800 A, LSIG on 1600 A frame)
3P, 4P · 32–1,600 A · 50 kA

2-pole moulded case circuit breaker for battery protection
2P · 125–250 A · 25–35 kA
Shown: the Himel HDM3 MCCB.3-pole high-voltage (690-1140 VAC) moulded case circuit breaker, thermal-magnetic
3P · 250–630 A · 36–40 kA
Shown: the Himel HDM3V battery-protection MCCB.DC moulded case circuit breaker, up to 1000 VDC
2P · 125–250 A · 15–50 kA
Try another word, or search every Himel product.
All 6 families on this page, with the values the May 2025 Himel price list prints. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.
| Family | Models | Poles | Rated current | Frames | Breaking capacity | Trip unit | Source |
|---|---|---|---|---|---|---|---|
| Himel HDM3 MCCB (Fixed Thermal-Magnetic) | 83 | 3P, 4P | 16–1,600 A | 100, 160, 250, 400, 630, 800, 1,600 A | 25–75 kA | Thermal-magnetic, fixed | p. 13, 14, 15, 16 |
| Himel HDM3S MCCB (Adjustable Thermal-Magnetic) | 30 | 3P, 4P | 25–630 A | 160, 250, 400, 630 A | 35–50 kA | Thermal-magnetic, adjustable | p. 18, 19 |
| Himel HDM3E MCCB (Electronic Trip) | 24 | 3P, 4P | 32–1,600 A | 125, 250, 400, 630, 800, 1,600 A | 50 kA | Electronic LSI, Electronic LSIG | p. 21, 22 |
| Himel HDM3V Battery Protection MCCB | 2 | 2P | 125–250 A | — | 25–35 kA | — | p. 9 |
| Himel CDMNE MCCB 690-1140VAC | 4 | 3P | 250–630 A | — | 36–40 kA | — | p. 13 |
| Himel M6Z DC MCCB | 3 | 2P | 125–250 A | — | 15–50 kA | C | p. 9 |
The 146 rows of these families exactly as the May 2025 Himel price list prints them, column for column. Where a cell is misprinted, a short note under the table says so.
Moulded case circuit breaker, fixed thermal-magnetic trip · 83 rows · the May 2025 Himel price list, p. 13, 14, 15, 16 · accessories: HDM3 / HDM3V / HDM3E Accessories
| Model | Type | Ratings | Frame | Icu | Version |
|---|---|---|---|---|---|
| HDM3100S1633XX | 3 Pole | 16 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S2033XX | 3 Pole | 20 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S2533XX | 3 Pole | 25 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S3233XX | 3 Pole | 32 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S4033XX | 3 Pole | 40 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S5033XX | 3 Pole | 50 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S6333XX | 3 Pole | 63 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S8033XX | 3 Pole | 80 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S10033XX | 3 Pole | 100 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3160S12533XX | 3 Pole | 125 Amps | 160 | 35kA | Standard breaking capacity |
| HDM3160S16033XX | 3 Pole | 160 Amps | 160 | 35kA | Standard breaking capacity |
| HDM3250S20033XX | 3 Pole | 200 Amps | 250 | 35kA | Standard breaking capacity |
| HDM3250S22533XX | 3 Pole | 225 Amps | 250 | 35kA | Standard breaking capacity |
| HDM3250S25033XX | 3 Pole | 250 Amps | 250 | 35kA | Standard breaking capacity |
| HDM3400F31533XX | 3 Pole | 315 Amps | 400 | 50kA | Standard breaking capacity |
| HDM3400F35033XX | 3 Pole | 350 Amps | 400 | 50kA | Standard breaking capacity |
| HDM3400F40033XX | 3 Pole | 400 Amps | 400 | 50kA | Standard breaking capacity |
| HDM3630F50033XX | 3 Pole | 500 Amps | 630 | 50kA | Standard breaking capacity |
| HDM3630F63033XX | 3 Pole | 630 Amps | 630 | 50kA | Standard breaking capacity |
| HDM3V800M80033XX | 3 Pole | 800 Amps | 800 | 50kA | Standard breaking capacity |
| HDM3100N1633XX | 3 Pole | 16 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N2033XX | 3 Pole | 20 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N2533XX | 3 Pole | 25 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N3233XX | 3 Pole | 32 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N4033XX | 3 Pole | 40 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N5033XX | 3 Pole | 50 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N6333XX | 3 Pole | 63 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N8033XX | 3 Pole | 80 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N10033XX | 3 Pole | 100 Amps | 100 | 50kA | High breaking capacity |
| HDM3160F12533XX | 3 Pole | 125 Amps | 160 | 50kA | High breaking capacity |
| HDM3160F16033XX | 3 Pole | 160 Amps | 160 | 50kA | High breaking capacity |
| HDM3250F20033XX | 3 Pole | 200 Amps | 250 | 50kA | High breaking capacity |
| HDM3250F22533XX | 3 Pole | 225 Amps | 250 | 50kA | High breaking capacity |
| HDM3250F25033XX | 3 Pole | 250 Amps | 250 | 50kA | High breaking capacity |
| HDM3400N31533XX | 3 Pole | 315 Amps | 400 | 70kA | High breaking capacity |
| HDM3400N35033XX | 3 Pole | 350 Amps | 400 | 70kA | High breaking capacity |
| HDM3400N40033XX | 3 Pole | 400 Amps | 400 | 70kA | High breaking capacity |
| HDM3630N50033XX | 3 Pole | 500 Amps | 630 | 70kA | High breaking capacity |
| HDM3630N63033XX | 3 Pole | 630 Amps | 630 | 70kA | High breaking capacity |
| HDM3V800N80033XX | 3 Pole | 800 Amps | 800 | 75kA | High breaking capacity |
| HDM31600N100033XX | 3 Pole | 1000 Amps | 1600 | 70kA | High breaking capacity |
| HDM31600N125033XX | 3 Pole | 1250 Amps | 1600 | 70kA | High breaking capacity |
| HDM31600N160033XX | 3 Pole | 1600 Amps | 1600 | 70kA | High breaking capacity |
| HDM3100S16B3XX | 4 Pole | 16 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S20B3XX | 4 Pole | 20 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S25B3XX | 4 Pole | 25 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S32B3XX | 4 Pole | 32 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S40B3XX | 4 Pole | 40 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S50B3XX | 4 Pole | 50 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S63B3XX | 4 Pole | 63 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S80B3XX | 4 Pole | 80 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3100S100B3XX | 4 Pole | 100 Amps | 100 | 25kA | Standard breaking capacity |
| HDM3160S125B3XX | 4 Pole | 125 Amps | 160 | 35kA | Standard breaking capacity |
| HDM3160S160B3XX | 4 Pole | 160 Amps | 160 | 35kA | Standard breaking capacity |
| HDM3250S200B3XX | 4 Pole | 200 Amps | 250 | 35kA | Standard breaking capacity |
| HDM3250S225B3XX | 4 Pole | 225 Amps | 250 | 35kA | Standard breaking capacity |
| HDM3250S250B3XX | 4 Pole | 250 Amps | 250 | 35kA | Standard breaking capacity |
| HDM3400F315B3XX | 4 Pole | 315 Amps | 400 | 35kA | Standard breaking capacity |
| HDM3400F350B3XX | 4 Pole | 350 Amps | 400 | 35kA | Standard breaking capacity |
| HDM3400F400B3XX | 4 Pole | 400 Amps | 400 | 50kA | Standard breaking capacity |
| HDM3630F500B3XX | 4 Pole | 500 Amps | 630 | 50kA | Standard breaking capacity |
| HDM3630F630B3XX | 4 Pole | 630 Amps | 630 | 50kA | Standard breaking capacity |
| HDM3V800M800B3XX | 4 Pole | 800 Amps | 800 | 50kA | Standard breaking capacity |
| HDM3100N16B3XX | 4 Pole | 16 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N20B3XX | 4 Pole | 20 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N25B3XX | 4 Pole | 25 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N32B3XX | 4 Pole | 32 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N40B3XX | 4 Pole | 40 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N50B3XX | 4 Pole | 50 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N63B3XX | 4 Pole | 63 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N80B3XX | 4 Pole | 80 Amps | 100 | 50kA | High breaking capacity |
| HDM3100N100B3XX | 4 Pole | 100 Amps | 100 | 50kA | High breaking capacity |
| HDM3160F125B3XX | 4 Pole | 125 Amps | 160 | 50kA | High breaking capacity |
| HDM3160F160B3XX | 4 Pole | 160 Amps | 160 | 50kA | High breaking capacity |
| HDM3250F200B3XX | 4 Pole | 200 Amps | 250 | 50kA | High breaking capacity |
| HDM3250F225B3XX | 4 Pole | 225 Amps | 250 | 50kA | High breaking capacity |
| HDM3250F250B3XX | 4 Pole | 250 Amps | 250 | 50kA | High breaking capacity |
| HDM3400N315B3XX | 4 Pole | 315 Amps | 400 | 70kA | High breaking capacity |
| HDM3400N350B3XX | 4 Pole | 350 Amps | 400 | 70kA | High breaking capacity |
| HDM3400N400B3XX | 4 Pole | 400 Amps | 400 | 70kA | High breaking capacity |
| HDM3630N500B3XX | 4 Pole | 500 Amps | 630 | 70kA | High breaking capacity |
| HDM3630N630B3XX | 4 Pole | 630 Amps | 630 | 70kA | High breaking capacity |
| HDM3V800N800B3XX | 4 Pole | 800 Amps | 800 | 75kA | High breaking capacity |
The 800 A codes carry the HDM3V prefix, as printed. The 1000-1600 A frame is printed in the 3-pole high-breaking table only.
Moulded case circuit breaker, adjustable thermal-magnetic trip · 30 rows · the May 2025 Himel price list, p. 18, 19 · accessories: HDM3S Accessories
| Model | Type | Ratings | Frame | Icu |
|---|---|---|---|---|
| HDM3S160M02531XX | 3 Pole | 25A | 160 | 35kA |
| HDM3S160M03231XX | 3 Pole | 32A | 160 | 35kA |
| HDM3S160M04031XX | 3 Pole | 40A | 160 | 35kA |
| HDM3S160M05031XX | 3 Pole | 50A | 160 | 35kA |
| HDM3S160M06333XX | 3 Pole | 63A | 160 | 35kA |
| HDM3S160M08033XX | 3 Pole | 80A | 160 | 35kA |
| HDM3S160M10033XX | 3 Pole | 100A | 160 | 35kA |
| HDM3S160M12533XX | 3 Pole | 125A | 160 | 35kA |
| HDM3S160M16033XX | 3 Pole | 160A | 160 | 35kA |
| HDM3S250M20033XX | 3 Pole | 200A | 250 | 35kA |
| HDM3S250M25033XX | 3 Pole | 250A | 250 | 35kA |
| HDM3S400M32033XX | 3 Pole | 320A | 400 | 50kA |
| HDM3S400M40033XX | 3 Pole | 400A | 400 | 50kA |
| HDM3S630M50033XX | 3 Pole | 500A | 630 | 50kA |
| HDM3S630M63033XX | 3 Pole | 630A | 630 | 50kA |
| HDM3S160M025B1XX | 4 Pole | 25A | 160 | 35kA |
| HDM3S160M032B1XX | 4 Pole | 32A | 160 | 35kA |
| HDM3S160M040B1XX | 4 Pole | 40A | 160 | 35kA |
| HDM3S160M050B1XX | 4 Pole | 50A | 160 | 35kA |
| HDM3S160M063B3XX | 4 Pole | 63A | 160 | 35kA |
| HDM3S160M080B3XX | 4 Pole | 80A | 160 | 35kA |
| HDM3S160M100B3XX | 4 Pole | 100A | 160 | 35kA |
| HDM3S160M125B3XX | 4 Pole | 125A | 160 | 35kA |
| HDM3S160M160B3XX | 4 Pole | 160A | 160 | 35kA |
| HDM3S250M200B3XX | 4 Pole | 200A | 250 | 35kA |
| HDM3S250M250B3XX | 4 Pole | 250A | 250 | 35kA |
| HDM3S400M320B3XX | 4 Pole | 320A | 400 | 50kA |
| HDM3S400M400B3XX | 4 Pole | 400A | 400 | 50kA |
| HDM3S630M500B3XX | 4 Pole | 500A | 630 | 50kA |
| HDM3S630M630B3XX | 4 Pole | 630A | 630 | 50kA |
Moulded case circuit breaker with adjustable electronic trip unit (LSI up to 800 A, LSIG on 1600 A frame) · 24 rows · the May 2025 Himel price list, p. 21, 22 · accessories: HDM3 / HDM3V / HDM3E Accessories, HDM3E 1600A Accessories
| Model | Type | Ratings | Frame | Icu | Trip unit |
|---|---|---|---|---|---|
| HDM3E125M3233XX | 3 Pole | 32A | 125 | 50kA | Electronic LSI |
| HDM3E125M6333XX | 3 Pole | 63A | 125 | 50kA | Electronic LSI |
| HDM3E125M10033XX | 3 Pole | 100A | 125 | 50kA | Electronic LSI |
| HDM3E125M12533XX | 3 Pole | 125A | 125 | 50kA | Electronic LSI |
| HDM3E250M16033XX | 3 Pole | 160A | 250 | 50kA | Electronic LSI |
| HDM3E250M25033XX | 3 Pole | 250A | 250 | 50kA | Electronic LSI |
| HDM3E400M40033XX | 3 Pole | 400A | 400 | 50kA | Electronic LSI |
| HDM3E630M63033XX | 3 Pole | 630A | 630 | 50kA | Electronic LSI |
| HDM3E800M80033XX | 3 Pole | 800A | 800 | 50kA | Electronic LSI |
| HDM3E125M32C3XX | 4 Pole | 32A | 125 | 50kA | Electronic LSI |
| HDM3E125M63C3XX | 4 Pole | 63A | 125 | 50kA | Electronic LSI |
| HDM3E125M100C3XX | 4 Pole | 100A | 125 | 50kA | Electronic LSI |
| HDM3E125M125C3XX | 4 Pole | 125A | 125 | 50kA | Electronic LSI |
| HDM3E250M160C3XX | 4 Pole | 160A | 250 | 50kA | Electronic LSI |
| HDM3E250M250C3XX | 4 Pole | 250A | 250 | 50kA | Electronic LSI |
| HDM3E400M400C3XX | 4 Pole | 400A | 400 | 50kA | Electronic LSI |
| HDM3E630M630C3XX | 4 Pole | 630A | 630 | 50kA | Electronic LSI |
| HDM3E800M800C3XX | 4 Pole | 800A | 800 | 50kA | Electronic LSI |
| HDM3E16M103F555L | 3 Pole | 1000A | 1600 | 50kA | Electronic LSIG |
| HDM3E16M123F555L | 3 Pole | 1250A | 1600 | 50kA | Electronic LSIG |
| HDM3E16M163F555L | 3 Pole | 1600A | 1600 | 50kA | Electronic LSIG |
| HDM3E16M104F555LT | 4 Pole | 1000A | 1600 | 50kA | Electronic LSIG |
| HDM3E16M124F555LT | 4 Pole | 1250A | 1600 | 50kA | Electronic LSIG |
| HDM3E16M164F555LT | 4 Pole | 1600A | 1600 | 50kA | Electronic LSIG |
2-pole moulded case circuit breaker for battery protection · 2 rows · the May 2025 Himel price list, p. 9
| Model | Type | Ratings | Breaking capacity |
|---|---|---|---|
| HDM3V125C12523XX | 2 Pole | 125 Amps | 25kA |
| HDM3V250S25023XX | 2 Pole | 250 Amps | 35kA |
3-pole high-voltage (690-1140 VAC) moulded case circuit breaker, thermal-magnetic · 4 rows · the May 2025 Himel price list, p. 13
| Model | Type | Ratings | Rated voltage | Icu |
|---|---|---|---|---|
| NE25F2503300 | 3 Pole | 250 Amps | 800 VAC | 36kA |
| NE32F3203300 | 3 Pole | 320 Amps | 800 VAC | 40kA |
| NE40F4003300 | 3 Pole | 400 Amps | 800 VAC | 40kA |
| NE63F6303300 | 3 Pole | 630 Amps | 800 VAC | 40kA |
The codes are printed with the “NE” prefix only.
DC moulded case circuit breaker, up to 1000 VDC · 3 rows · the May 2025 Himel price list, p. 9
| Model | Type | Ratings | Voltage | Breaking capacity |
|---|---|---|---|---|
| M6Z125S1252D02 | 2 Pole | 125 Amps | 250 VDC | 15kA |
| M6Z250H2002D02 | 2 Pole | 200 Amps | 1000 VDC | 50kA |
| M6Z250H2502D02 | 2 Pole | 250 Amps | 1000 VDC | 50kA |
Printed note: “Ratings are available upto 800A and 1000VDC.”
The same products from every circuit breaker brand FMST supplies as an Authorized Partner & Distributor, on one page each.
FMST quotes Himel MCCBs on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example HDM3100S1633XX and HDM3S160M02531XX) and FMST replies with the current rate.
HDM3 (83 models), HDM3S (30 models), HDM3E (24 models), HDM3V Battery (2 models), CDMNE (4 models) and M6Z DC (3 models): 6 families and 146 models, each row as the May 2025 Himel price list prints it.
As printed: HDM3: Moulded case circuit breaker, fixed thermal-magnetic trip, 16–1,600 A in 100, 160, 250, 400, 630, 800, 1,600 A frames, 25–75 kA; HDM3S: Moulded case circuit breaker, adjustable thermal-magnetic trip, 25–630 A in 160, 250, 400, 630 A frames, 35–50 kA; HDM3E: Moulded case circuit breaker with adjustable electronic trip unit (LSI up to 800 A, LSIG on 1600 A frame), 32–1,600 A in 125, 250, 400, 630, 800, 1,600 A frames, 50 kA; HDM3V Battery: 2-pole moulded case circuit breaker for battery protection, 125–250 A, 25–35 kA; CDMNE: 3-pole high-voltage (690-1140 VAC) moulded case circuit breaker, thermal-magnetic, 250–630 A, 36–40 kA; M6Z DC: DC moulded case circuit breaker, up to 1000 VDC, 125–250 A, 15–50 kA. Rows that print the same code for 3 and 4 poles are separate rows in the tables below.
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of Himel in Lahore, supplying genuine Himel MCCBs to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.
WhatsApp the order codes from this page, or your load list, and FMST quotes genuine Himel. Electrical desk: 0306 4758850. All Himel categories: Himel circuit breakers.