Himel HDP6 / HDP17Z Motor Protection Circuit Breaker
Motor protection circuit breaker (MPCB), 32 A and 80 A frames
0.4–80 A · 0.12–25 kW
FMST lists 3 families of Himel motor protection devices (HDP6 / HDP17Z, HDR3 / HDR3s and HDS3) with 64 models exactly as the May 2025 Himel price list prints them. FMST is an Authorized Partner & Distributor of Himel in Lahore.



Himel’s own photos, printed specifications and every order code. Tap a card for the full table.

Motor protection circuit breaker (MPCB), 32 A and 80 A frames
0.4–80 A · 0.12–25 kW

Thermal overload relay for HDC3 contactors
0.63–630 A

Enclosed direct-on-line (DOL) magnetic motor starter, IP54
1–40 A · 0.37–18.5 kW
Try another word, or search every Himel product.
All 3 families on this page, with the values the May 2025 Himel price list prints. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.
| Family | Models | Setting range | Motor power | Breaking capacity | Standard | Source |
|---|---|---|---|---|---|---|
| Himel HDP6 / HDP17Z Motor Protection Circuit Breaker | 15 | 0.4–80 A | 0.12–25 kW | — | IEC 60947-2 | p. 31 |
| Himel HDR3 / HDR3s Thermal Overload Relay | 38 | 0.63–630 A | — | — | IEC 60947-2 (as printed) | p. 30 |
| Himel HDS3 Magnetic DOL Starter | 11 | 1–40 A | 0.37–18.5 kW | — | IEC 60947-4 | p. 32 |
The 64 rows of these families exactly as the May 2025 Himel price list prints them, column for column. Where a cell is misprinted, a short note under the table says so.
Motor protection circuit breaker (MPCB), 32 A and 80 A frames · 15 rows · the May 2025 Himel price list, p. 31 · accessories: HDP6 / HDP17Z MPCB Accessories
| Model | Range | Power (kW) | Recommended contactor |
|---|---|---|---|
| HDP632P63 | 0.4-0.63A | 0.12kW | HDC3 - 09 |
| HDP6321 | 0.63-1A | 0.25kW | HDC3 - 09 |
| HDP6321P6 | 1-1.6A | 0.37kW | HDC3 - 09 |
| HDP6322P5 | 1.6-2.5A | 0.75kW | HDC3 - 09 |
| HDP6324 | 2.5-4A | 1.5kW | HDC3 - 09 |
| HDP6326P3 | 4-6.3A | 2.2kW | HDC3 - 09 |
| HDP63210 | 6-10A | 4kW | HDC3 - 09 |
| HDP63214 | 9-14A | 5.5kW | HDC3 - 12 |
| HDP63218 | 13-18A | 7.5kW | HDC3 - 18 |
| HDP63223 | 17-23A | 9kW | HDC3 - 25 |
| HDP63225 | 20-25A | 11kW | HDC3 - 25 |
| HDP63232 | 24-32A | 15kW | HDC3 - 32 |
| HDP17Z8040 | 25-40A | 16kW | HDC3 - 40 |
| HDP17Z8063 | 40-63A | 20kW | HDC3 - 65 |
| HDP17Z8080 | 56-80A | 25kW | HDC3 - 80 |
Thermal overload relay for HDC3 contactors · 38 rows · the May 2025 Himel price list, p. 30
| Model | Range | Type (contactor) |
|---|---|---|
| HDR3s251 | 0.63~1 A | HDC3 9~38 |
| HDR3s251P6 | 1~1.6 A | HDC3 9~38 |
| HDR3s252P5 | 1.6~2.5 A | HDC3 9~38 |
| HDR3s254 | 2.5~4 A | HDC3 9~38 |
| HDR3s256 | 4~6 A | HDC3 9~38 |
| HDR3s258 | 5.5~8 A | HDC3 9~38 |
| HDR3s2510 | 7~10 A | HDC3 9~38 |
| HDR3s2513 | 9~13 A | HDC3 12~38 |
| HDR3s2518 | 12~18 A | HDC3 18~38 |
| HDR3s2525 | 17~25 A | HDC3 25~38 |
| HDR3s3832 | 23~32 A | HDC3 32~38 |
| HDR3s3840 | 30~40 A | HDC3 32~38 |
| HDR3s9310 | 7~10 A | HDC3 40~95 |
| HDR3s9313 | 9~13 A | HDC3 40~95 |
| HDR3s9318 | 12~18 A | HDC3 40~95 |
| HDR3s9325 | 17~25 A | HDC3 40~95 |
| HDR3s9332 | 23~32 A | HDC3 40~95 |
| HDR3s9340 | 30~40 A | HDC3 40~95 |
| HDR3s9350 | 37~50 A | HDC3 50~95 |
| HDR3s9365 | 48~65 A | HDC3 50~95 |
| HDR3s9370 | 55~70 A | HDC3 65~95 |
| HDR3s9380 | 63~80 A | HDC3 80~95 |
| HDR3s9393 | 80~93 A | HDC3 95 |
| HDR3s18565 | 48~65 A | HDC3 120~185 |
| HDR3s18570 | 55~70 A | HDC3 120~185 |
| HDR3s18580 | 63~80 A | HDC3 120~185 |
| HDR3s18595 | 75~95 A | HDC3 120~185 |
| HDR3s185115 | 90~115 A | HDC3 120~185 |
| HDR3s185135 | 105~135 A | HDC3 120~185 |
| HDR3s185150 | 120~150 A | HDC3 120~185 |
| HDR3s185160 | 130~160 A | HDC3 120~185 |
| HDR3s185185 | 150~185 A | HDC3 120~185 |
| HDR3s630200F | 145~200 A | HDC3 225~630 |
| HDR3s630250F | 180~250 A | HDC3 225~630 |
| HDR3s630320 | 230~320 A | HDC3 225~630 |
| HDR3s630400F | 290~400 A | HDC3 225~630 |
| HDR3s630480F | 350~480 A | HDC3 225~630 |
| HDR3s630630F | 460~630 A | HDC3 225~630 |
The last three contactor cells are printed “HDC3 225~631”, “225~632” and “225~633”, a numbering slip for HDC3 225~630. The specification line lists a “680A” frame; the largest range printed is 460~630 A.
Enclosed direct-on-line (DOL) magnetic motor starter, IP54 · 11 rows · the May 2025 Himel price list, p. 32
| Model | Range | Power (kW) |
|---|---|---|
| HDS338B09Q71P6 | 1-1.6A | 0.37kW |
| HDS338B09Q72P5 | 1.6-2.5A | 0.75kW |
| HDS338B09Q704 | 2.5-4A | 1.5kW |
| HDS338B09Q706 | 4-6A | 2.2kW |
| HDS338B09Q708 | 5.5-8A | 3kW |
| HDS338B12Q710 | 7-10A | 4kW |
| HDS338B18Q713 | 9-13A | 5.5kW |
| HDS338B25Q718 | 12-18A | 7.5kW |
| HDS338B25Q725 | 17-25A | 11kW |
| HDS338B25Q732 | 23-32A | 15kW |
| HDS338B25Q740 | 30-40A | 18.5kW |
FMST quotes Himel motor protection devices on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example HDP632P63 and HDR3s251) and FMST replies with the current rate.
HDP6 / HDP17Z (15 models), HDR3 / HDR3s (38 models) and HDS3 (11 models): 3 families and 64 models, each row as the May 2025 Himel price list prints it.
A motor protection circuit breaker (MPCB, or manual motor starter) combines short-circuit and adjustable overload protection for one motor; a thermal overload relay mounts on a contactor and opens it on overload; a DOL starter is a contactor and overload relay in an enclosure that starts a motor direct on line. As printed: HDP6 / HDP17Z 0.4–80 A, 0.12–25 kW; HDR3 / HDR3s 0.63–630 A; HDS3 1–40 A, 0.37–18.5 kW.
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of Himel in Lahore, supplying genuine Himel motor protection devices to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.
WhatsApp the order codes from this page, or your load list, and FMST quotes genuine Himel. Electrical desk: 0306 4758850. All Himel categories: Himel circuit breakers.