Himel HDB3VR / HDB6VR RCCB
Residual current circuit breaker (RCCB / ELCB), earth-leakage protection without overcurrent
2P, 4P · 16–100 A · 30/300mA
FMST lists 3 families of Himel RCCBs and RCBOs (HDB3VR / HDB6VR, HDB3LE / HDB3WLE125 and HDB3LTH) with 20 models exactly as the May 2025 Himel price list prints them. FMST is an Authorized Partner & Distributor of Himel in Lahore.



Himel’s own photos, printed specifications and every order code. Tap a card for the full table.

Residual current circuit breaker (RCCB / ELCB), earth-leakage protection without overcurrent
2P, 4P · 16–100 A · 30/300mA

Residual current breaker with overcurrent protection (RCBO)
2P, 4P · 6–125 A · 6 kA

1P+N RCBO with flying-lead (long tail) connection
1P+N · 6–50 A · 30/300mA
Try another word, or search every Himel product.
All 3 families on this page, with the values the May 2025 Himel price list prints. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.
| Family | Models | Poles | Rated current | Sensitivity | Breaking capacity | Standard | Source |
|---|---|---|---|---|---|---|---|
| Himel HDB3VR / HDB6VR RCCB | 14 | 2P, 4P | 16–100 A | 30/300mA | — | IEC 61008-1 | p. 11 |
| Himel HDB3LE / HDB3WLE125 RCBO | 5 | 2P, 4P | 6–125 A | — | 6 kA | 61009-1 (printed without prefix) | p. 11 |
| Himel HDB3LTH Long-Tail RCBO | 1 | 1P+N | 6–50 A | 30/300mA | 10 kA | 61009-1 (printed without prefix) | p. 12 |
The 20 rows of these families exactly as the May 2025 Himel price list prints them, column for column. Where a cell is misprinted, a short note under the table says so.
Residual current circuit breaker (RCCB / ELCB), earth-leakage protection without overcurrent · 14 rows · the May 2025 Himel price list, p. 11
| Model | Type | Ratings | Sensitivity |
|---|---|---|---|
| HDB3VR216 | 2 Pole | 16 Amps | 30/300mA |
| HDB3VR220 | 2 Pole | 20 Amps | 30/300mA |
| HDB3VR225 | 2 Pole | 25 Amps | 30/300mA |
| HDB3VR232 | 2 Pole | 32 Amps | 30/300mA |
| HDB3VR240 | 2 Pole | 40 Amps | 30/300mA |
| HDB3VR263 | 2 Pole | 63 Amps | 30/300mA |
| HDB3VR416 | 4 Pole | 16 Amps | 30/300mA |
| HDB3VR420 | 4 Pole | 20 Amps | 30/300mA |
| HDB3VR425 | 4 Pole | 25 Amps | 30/300mA |
| HDB3VR432 | 4 Pole | 32 Amps | 30/300mA |
| HDB3VR440 | 4 Pole | 40 Amps | 30/300mA |
| HDB3VR463 | 4 Pole | 63 Amps | 30/300mA |
| HDB3VR480 | 4 Pole | 80 Amps | 30/300mA |
| HDB3VR4100 | 4 Pole | 100 Amps | 30/300mA |
Residual current breaker with overcurrent protection (RCBO) · 5 rows · the May 2025 Himel price list, p. 11
| Model | Type | Ratings | Breaking capacity |
|---|---|---|---|
| HDB3LE2C | 2 Pole | 6/10/16/20/25/32/40 Amps | 6kA |
| HDB3LE2C | 2 Pole | 50/63 Amps | 6kA |
| HDB3LE4C | 4 Pole | 6/10/16/20/25/32/40 Amps | 6kA |
| HDB3LE4C | 4 Pole | 50/63 Amps | 6kA |
| HDB3wLE1254C | 4 Pole | 80/100/125 Amps | 6kA |
The specification line prints the ratings as “6, 10, 16, 20, 25, 32, 40, 50, 63, 10, 100, 125A”; the table lists 80, 100 and 125 A for the 125 A frame. No sensitivity (mA) is printed for this table.
1P+N RCBO with flying-lead (long tail) connection · 1 row · the May 2025 Himel price list, p. 12
| Model | Type | Ratings | Sensitivity | Breaking capacity |
|---|---|---|---|---|
| HDB3LTH1C | 1P+N | 6/10/16/20/25/32/40/50 Amps | 30/300mA | 10kA |
The same products from every circuit breaker brand FMST supplies as an Authorized Partner & Distributor, on one page each.
FMST quotes Himel RCCBs and RCBOs on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example HDB3VR216 and HDB3LE2C) and FMST replies with the current rate.
HDB3VR / HDB6VR (14 models), HDB3LE / HDB3WLE125 (5 models) and HDB3LTH (1 model): 3 families and 20 models, each row as the May 2025 Himel price list prints it.
An RCCB (also called an ELCB) trips on earth leakage to protect people from electric shock, but gives no overload or short-circuit protection, so it is used with MCBs; an RCBO is an RCCB and an MCB in one device. Himel RCCBs here: HDB3VR / HDB6VR. RCBOs: HDB3LE / HDB3WLE125 and HDB3LTH.
30 mA is the sensitivity used to protect people against electric shock; 100 mA and 300 mA protect installations against fire from leakage. As printed: HDB3VR / HDB6VR 30/300mA; HDB3LTH 30/300mA.
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of Himel in Lahore, supplying genuine Himel RCCBs and RCBOs to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.
WhatsApp the order codes from this page, or your load list, and FMST quotes genuine Himel. Electrical desk: 0306 4758850. All Himel categories: Himel circuit breakers.