Terasaki TemBreak PRO MCCB / ELCB Accessories
Internally and externally mounted accessories and electronic OCR types for TemBreak PRO breakers
FMST lists 6 families of Terasaki MCCB, ACB and DIN-rail accessories (TemBreak PRO Accessories, TemBreak PRO Motor Operators, TemPower2 ACB Accessories, TemPower PRO ACB Accessories, TemPlug70 and TD3 Accessories) with 167 models exactly as Terasaki’s own catalogues and product pages print them. FMST is an Authorized Partner & Distributor of Terasaki in Lahore.




Terasaki’s own photos, printed specifications and every order code. Tap a card for the full table.

Internally and externally mounted accessories and electronic OCR types for TemBreak PRO breakers

Motor operator for remote ON / OFF / reset of TemBreak PRO breakers, with interlock cables

Over-current releases, trip devices, auxiliary and position switches, lifters and test equipment for TemPower2 ACBs

Over-current releases, communication modules, position switches and other accessories for TemPower PRO ACBs

Bus-coupled plug-in base for TemBreak PRO breakers in distribution boards
Shown: Terasaki TD3 MCBs, which these accessories fit.Auxiliary, alarm, trip, lock and residual-current add-ons for TD3 devices
Try another word, or search every Terasaki product.
All 6 families on this page, with the values Terasaki’s own catalogues and product pages print. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.
| Family | Models | For | Source |
|---|---|---|---|
| Terasaki TemBreak PRO MCCB / ELCB Accessories | 28 | fits TemBreak PRO Economical, TemBreak PRO Standard, TemBreak PRO Standard 50-100 kA, TemBreak PRO High-fault, TemBreak PRO Current limiting, TemBreak PRO Motor protection, TemBreak PRO Switch-disconnectors, TemBreak PRO Non-automatic trip breakers, TemBreak PRO with Earth Leakage Alarm, Single-phase 3-wire with Earth Leakage Alarm, Single-phase 3-wire Neutral Open-phase Protection, TemBreak PRO Earth Leakage Economical, TemBreak PRO Earth Leakage Standard, TemBreak PRO Earth Leakage High-fault, TemBreak PRO Earth Leakage for Motor Protection and Single-phase 3-wire Earth Leakage Circuit Breakers | Catalogue 23-I68E, ch. 6 |
| Terasaki TemBreak PRO Motor Operators (MC) | 16 | fits TemBreak PRO Economical, TemBreak PRO Standard, TemBreak PRO Standard 50-100 kA, TemBreak PRO High-fault, TemBreak PRO Current limiting, TemBreak PRO Motor protection, TemBreak PRO Switch-disconnectors, TemBreak PRO Non-automatic trip breakers, TemBreak PRO with Earth Leakage Alarm, Single-phase 3-wire with Earth Leakage Alarm, Single-phase 3-wire Neutral Open-phase Protection, TemBreak PRO Earth Leakage Economical, TemBreak PRO Earth Leakage Standard, TemBreak PRO Earth Leakage High-fault, TemBreak PRO Earth Leakage for Motor Protection and Single-phase 3-wire Earth Leakage Circuit Breakers | Catalogue 23-I68E, pp. 6-31 to 6-34 |
| Terasaki TemPower2 ACB Accessories | 52 | fits TemPower2 | Catalogue 18-I55E, pp. 18-39 |
| Terasaki TemPower PRO ACB Accessories | 47 | fits TemPower PRO and TemPower PRO Switch Disconnectors | Catalogue 25-I58E, pp. 7-54 |
| Terasaki TemPlug70 Bus-coupled Plug-in Bases | 14 | fits TemBreak PRO Economical, TemBreak PRO Standard, TemBreak PRO Standard 50-100 kA, TemBreak PRO High-fault, TemBreak PRO Motor protection, TemBreak PRO Switch-disconnectors, TemBreak PRO with Earth Leakage Alarm, TemBreak PRO Earth Leakage Economical, TemBreak PRO Earth Leakage Standard, TemBreak PRO Earth Leakage High-fault and TemBreak PRO Earth Leakage for Motor Protection | TemPlug70 page |
| Terasaki TD3 DIN Modular Protection Accessories | 10 | fits TD3 Miniature Circuit Breakers and TD3 RCCBs and RCBOs | TD3 leaflet 2022 |
The 167 rows of these families exactly as Terasaki’s own catalogues and product pages print them, column for column. Where a cell is misprinted, a short note under the table says so.
Internally and externally mounted accessories and electronic OCR types for TemBreak PRO breakers · 28 rows · Terasaki TemBreak PRO catalogue 23-I68E, accessories chapter (pp. 6-1 to 6-29)
| Code | Accessory | Group | Description (as printed) | Catalogue page |
|---|---|---|---|---|
| AL | Alarm switch | Internally mounted | Provides an electrical indication that the breaker is in a tripped state. | 6-14 |
| AX | Auxiliary switch | Internally mounted | Provides an electrical indication that the breaker is in a ON or OFF state. | 6-14 |
| SH | Shunt trip device | Internally mounted | Electrically trips the breaker open from a remote location. | 6-14 |
| UV | Undervoltage trip device | Internally mounted | Trips the breaker open when the circuit voltage lowers; can also be used to trip the breaker open from a remote location. Combined use of SH and UV is not available. | 6-14 |
| HA | Toggle extension | Externally mounted | Lessens the force required to close, open or reset the breaker. | 6-29 |
| MC | Motor operator | Externally mounted | Allows electrical operation (closing, opening and resetting) of the breaker. Types in family tembreak-pro-motor-operators. | 6-29 |
| HB | External operating handle, breaker-mounted | Externally mounted | The handle is mounted directly on the breaker; allows a breaker installed in a switchboard or box to be operated from outside. | 6-29 |
| HP | External operating handle, door-mounted (depth adjustable) | Externally mounted | The handle is coupled to the breaker through a shaft. | 6-29 |
| HE | External operating handle, door-mounted (depth fixed) | Externally mounted | Door-mounted handle with fixed depth. | 6-29 |
| MS | Mechanical interlock, slide type | Externally mounted | Provides an interlock that allows one of two breakers to be closed. | 6-29 |
| MB | Mechanical interlock, rear-connected type | Externally mounted | Provides an interlock that allows one of two breakers to be closed. | 6-29 |
| ML | Mechanical interlock, link type | Externally mounted | Provides an interlock that allows one of two breakers to be closed. | 6-29 |
| MW | Mechanical interlock, wire type | Externally mounted | Provides an interlock that allows one of two breakers to be closed. | 6-29 |
| HH | Toggle holder | Externally mounted | Holds the breaker ON or OFF when simply fitted onto the breaker toggle. | 6-29 |
| HL | Toggle lock | Externally mounted | Allows the breaker to be locked ON or OFF with commercially available padlocks. | 6-29 |
| CF | Terminal cover for front-connected breakers | Externally mounted | Prevents live parts of the breaker from being exposed. | 6-29 |
| CR | Terminal cover for rear-connected and plug-in breakers | Externally mounted | Prevents live parts of the breaker from being exposed. | 6-29 |
| CS | Terminal cover for front-connected breakers with cable clamps | Externally mounted | Prevents live parts of the breaker from being exposed. | 6-29 |
| BA | Interpole barrier | Externally mounted | Enhances electrical insulation between poles and prevents short circuit due to electrically conductive foreign matter. | 6-29 |
| TF | Terminal block | Externally mounted | Terminates lead wires from internally mounted accessories. | 6-29 |
| TB | Flush-mounted (flush plate) auxiliary circuit terminal block | Externally mounted | Optional lead-wire termination for flush-mounted breakers. | 6-1, 6-14 |
| DF | Door flange | Externally mounted | Intended to cover the cutout of a switchboard panel from the front. | 6-29 |
| - | DIN rail adaptor | Externally mounted | Allows the breaker to be mounted on DIN rails (no symbol printed in this catalogue; the European catalogue prints DA). | 6-29 |
| - | Plug-in auxiliary circuit terminal block | Externally mounted | Auxiliary circuit (self-engaging) terminals - standard lead wire ending for plug-in breakers. | 6-1, 6-14 |
| TPOT | TPOT type electronic OCR | OCR for electronic breakers | Three elements: long time-delay, short time-delay and instantaneous trip, plus preferential trip alarm; six setting dials. Applicable: PS125-NE/PE, PS250-NE/PE, PS400-NE/GE, PH400-CE, PS630-NE/GE, PH630-CE. | 6-2 |
| TPOP | TPOP type electronic OCR | OCR for electronic breakers | Long time-delay, short time-delay, instantaneous and ground fault trip with preferential trip alarm; 4-pole products also have N-phase protection; seven dials. Applicable: as TPOT. | 6-2 |
| XOU | XOU type electronic OCR | OCR for electronic breakers | Two front dials select the rated current and one of seven protection characteristics (1 generator, 2-4 general feeder, 5-7 motor protection); protection codes A, AP, AN, APN, AG, APG, AGN, APGN. Applicable: H225-NE, H400-NE, L400-NE, S630-NE, H630-NE, L630-NE, S800-NE/RE/PE, H800-NE, L800-NE, S1000-CE, S1250-NE/GE, S1600-NE. | 6-6 |
| XOS | XOS type electronic OCR | OCR for electronic breakers | Independently adjustable long time-delay, short time-delay, instantaneous and ground fault trip; ramp or definite-time short time-delay (SHORT TIME I²t switch); pre-trip alarm. Applicable: TL-1000NE, TL-1200NE, XS2000NE, XS2500NE, XS3200NE. | 6-10 |
Motor operator for remote ON / OFF / reset of TemBreak PRO breakers, with interlock cables · 16 rows · Terasaki TemBreak PRO catalogue 23-I68E, motor operators (pp. 6-31 to 6-34)
| Model | Type / item | Applicable breakers (E/S/H/L series as printed) | Rated operational voltage | Operating time (s) | Weight | Catalogue page |
|---|---|---|---|---|---|---|
| T2MC12 | Motor driven | S: S100-GF, S125-GF, ZAS50-GF, ZAS100-GF, ZAS125-GF, ZS100-GF, ZS125-GF | 100-110V AC, 200-220V AC, 230-240V AC, 24V DC, 48V DC, 100-110V DC, 200-220V DC | 0.1 | 1.4kg | 6-31 |
| T2MC25 | Motor driven | S: ZAS225-GF, ZAS250-GF, ZS225-GF, ZS250-GF; H: H100-NF, H125-NF, H225-NF/NE, H250-NF; L: L100-NF, L125-NF, L225-NF, L250-NF | 100-110V AC, 200-220V AC, 230-240V AC, 24V DC, 48V DC, 100-110V DC, 200-220V DC | 0.1 | 1.4kg | 6-31 |
| T2MC25L | Motor driven | E: E250-SF, ZAE250-SF, NAE250-SF, NE250-SF, ZE250-SF, ZNE250-SF; S: S250-SF, S250-SM/SN, ZAS250-SF, NAS250-SF, NS250-SF, ZS250-SF, ZS250-SM, ZNS250-SF | 100-110V AC, 200-220V AC, 230-240V AC, 24V DC, 48V DC, 100-110V DC, 200-220V DC | 0.1 | 1.4kg | 6-31 |
| TPMC16S | Motor driven | S: PS50-PF, PS125-NF/PF, PS125-NN, PS125-NE/PE | AC100-110V, AC200-220V, AC230-240V, DC24V, DC48V, DC100-110V, DC200-220V | 0.1 | 1.4kg | 6-31 |
| TPMC25S | Motor driven | S: PS250-PF, PS250-NN, PS250-NE/PE | AC100-110V, AC200-220V, AC230-240V, DC24V, DC48V, DC100-110V, DC200-220V | 0.1 | 1.4kg | 6-31 |
| T2MC40 | Spring charged | E: E400-NF, ZAE400-NF, NAE400-NF, NE400-NF, ZE400-NF, ZNE400-NF; S: ZAS400-NF/GF, NAS400-NF, NS400-NF, ZS400-NF/GF, ZNS400-NF; H: H400-NE; L: L400-NE | 100-240V AC, 24-48V DC, 100-120V DC | 0.1 (ON), 1.5 (OFF/RESET) | 3.5kg | 6-32 |
| TPMC63S | Spring charged | S: PS400-CF/NF/GF, PS400-NE/GE/NN, PS630-CF/NF/GF, PS630-NE/GE/NN; H: PH400-CF/CE, PH630-CF/CE | 100-240V AC, 24-48V DC, 100-120V DC | 0.1 (ON), 1.5 (OFF/RESET) | 3.5kg | 6-32 |
| T2MC80 | Spring charged | S: S630-CF/NF/NE/GN, ZAS630-CF/NF, NS630-NF, ZS630-CF/NF, S800-CF/NF/RF/PF, S800-NE/RE/PE/NN, ZAS800-CF/NF, NS800-NF, ZS800-CF/NF, S1000-CE/NN; H: H630-NE, H800-NE; L: L630-NE, L800-NE | 100-240V AC, 24-48V DC, 100-120V DC | 0.1 (ON), 1.5 (OFF/RESET) | 3.5kg | 6-32 |
| T2MCX6 | Spring charged | S1250-NE/GE/NN, S1600-NE/NN | AC100-115V, AC200-230V, DC100-110V, DC24V | 0.06 (ON max), 3 (OFF/RESET) | 6.4kg | 6-34 |
| XMD9 | Spring charged | TL-1000NE, TL-1200NE | AC100-115V, AC200-230V, DC100-110V, DC24V | 0.06 (ON max), 3 (OFF/RESET) | 6.4kg | 6-34 |
| T2MM25L05 | Electrical interlock cable, 500mm | Electrical interlock between T2MC12, T2MC25/25L, TPMC16S and TPMC25S types | - | - | - | 6-33 |
| T2MM25L15 | Electrical interlock cable, 1500mm | Electrical interlock between T2MC12, T2MC25/25L, TPMC16S and TPMC25S types | - | - | - | 6-33 |
| T2MM40L06 | Electrical interlock cable, 600mm | Electrical interlock between T2MC40, T2MC80 and TPMC63S types | - | - | - | 6-33 |
| T2MM40L21 | Electrical interlock cable, 2100mm | Electrical interlock between T2MC40, T2MC80 and TPMC63S types | - | - | - | 6-33 |
| T2MM40S06 | Electrical interlock cable, 600mm | Electrical interlock between T2MC40 (or TPMC63S, T2MC80) and T2MC12 types (or T2MC25, TPMC16S, TPMC25S types) | - | - | - | 6-33 |
| T2MM40S21 | Electrical interlock cable, 2100mm | Electrical interlock between T2MC40 (or TPMC63S, T2MC80) and T2MC12 types (or T2MC25, TPMC16S, TPMC25S types) | - | - | - | 6-33 |
Over-current releases, trip devices, auxiliary and position switches, lifters and test equipment for TemPower2 ACBs · 52 rows · Terasaki TemPower2 catalogue 18-I55E, accessories (pp. 18 to 39)
| Model | Accessory | Printed details | Catalogue page |
|---|---|---|---|
| AGR-11BL | Over-current release (OCR), L-characteristic | Standard OCR with adjustment dial; for general feeder circuits | 24 |
| AGR-21BL | Over-current release (OCR), L-characteristic | Standard OCR with LCD (backlit LCD optional); for general feeder circuits | 24 |
| AGR-31BL | Over-current release (OCR), L-characteristic | Enhanced OCR with backlit LCD; for general feeder circuits | 24 |
| AGR-21BR | Over-current release (OCR), R-characteristic | Standard OCR with LCD; R-characteristic long time-delay (five types) for general feeder circuits | 24 |
| AGR-31BR | Over-current release (OCR), R-characteristic | Enhanced OCR with backlit LCD; R-characteristic for general feeder circuits | 24 |
| AGR-21BS | Over-current release (OCR), S-characteristic | Standard OCR with LCD; for generator protection | 24 |
| AGR-22BS | Over-current release (OCR), S-characteristic | Standard OCR with LCD; for generator protection | 24 |
| AGR-31BS | Over-current release (OCR), S-characteristic | Enhanced OCR with backlit LCD; for generator protection | 24 |
| AVR-1C | Continuously-rated shunt trip device | AC100-240V / DC24-220V rated operational voltages; opening time max. 50 ms (60 ms for AR6) | 22 |
| AQR-1 | Capacitor trip device | Rated voltage AC100-120V; with the continuously-rated shunt trip it trips the ACB within 30 s after a large voltage drop | 22 |
| AUR-1CS | Undervoltage trip control device (instantaneous) | Instantaneous trip (below 200 ms) when the control voltage drops below the opening voltage | 23 |
| AUR-1CD | Undervoltage trip control device (delayed) | Delayed trip when the control voltage stays below the opening voltage for at least 500 ms | 23 |
| TSE-30M | Step-down transformer (external) | 300VA; 450/220V for AC410-470V and 380/220V for AC350-395V control voltage | 21 |
| AXR-004 | Auxiliary switch | 4c normal contacts for general service (standard arrangement) | 38 |
| AXR-007 | Auxiliary switch | 7c normal contacts | 38 |
| AXR-304 | Auxiliary switch | 4c normal + 3c gold contacts for microload | 38 |
| AXR-010 | Auxiliary switch | 10c normal contacts | 38 |
| AXR-307 | Auxiliary switch | 7c normal + 3c gold contacts for microload | 38 |
| ALR-0110P | Position switch | 2c; INSERT 0, ISOLATED 1, TEST 1, CONN 0 | 19 |
| ALR-0101P | Position switch | 2c; INSERT 0, ISOLATED 1, TEST 0, CONN 1 | 19 |
| ALR-0011P | Position switch | 2c; INSERT 0, ISOLATED 0, TEST 1, CONN 1 | 19 |
| ALR-0200P | Position switch | 2c; INSERT 0, ISOLATED 2, TEST 0, CONN 0 | 19 |
| ALR-0020P | Position switch | 2c; INSERT 0, ISOLATED 0, TEST 2, CONN 0 | 19 |
| ALR-0002P | Position switch | 2c; INSERT 0, ISOLATED 0, TEST 0, CONN 2 | 19 |
| ALR-1111P | Position switch | 4c; INSERT 1, ISOLATED 1, TEST 1, CONN 1 | 19 |
| ALR-1210P | Position switch | 4c; INSERT 1, ISOLATED 2, TEST 1, CONN 0 | 19 |
| ALR-1201P | Position switch | 4c; INSERT 1, ISOLATED 2, TEST 0, CONN 1 | 19 |
| ALR-0211P | Position switch | 4c; INSERT 0, ISOLATED 2, TEST 1, CONN 1 | 19 |
| ALR-1120P | Position switch | 4c; INSERT 1, ISOLATED 1, TEST 2, CONN 0 | 19 |
| ALR-1021P | Position switch | 4c; INSERT 1, ISOLATED 0, TEST 2, CONN 1 | 19 |
| ALR-0121P | Position switch | 4c; INSERT 0, ISOLATED 1, TEST 2, CONN 1 | 19 |
| ALR-1102P | Position switch | 4c; INSERT 1, ISOLATED 1, TEST 0, CONN 2 | 19 |
| ALR-1012P | Position switch | 4c; INSERT 1, ISOLATED 0, TEST 1, CONN 2 | 19 |
| ALR-0112P | Position switch | 4c; INSERT 0, ISOLATED 1, TEST 1, CONN 2 | 19 |
| ALR-0220P | Position switch | 4c; INSERT 0, ISOLATED 2, TEST 2, CONN 0 | 19 |
| ALR-0202P | Position switch | 4c; INSERT 0, ISOLATED 2, TEST 0, CONN 2 | 19 |
| ALR-0022P | Position switch | 4c; INSERT 0, ISOLATED 0, TEST 2, CONN 2 | 19 |
| ALR-1030P | Position switch | 4c; INSERT 1, ISOLATED 0, TEST 3, CONN 0 | 19 |
| ALR-0130P | Position switch | 4c; INSERT 0, ISOLATED 1, TEST 3, CONN 0 | 19 |
| ALR-0031P | Position switch | 4c; INSERT 0, ISOLATED 0, TEST 3, CONN 1 | 19 |
| ALR-1003P | Position switch | 4c; INSERT 1, ISOLATED 0, TEST 0, CONN 3 | 19 |
| ALR-0103P | Position switch | 4c; INSERT 0, ISOLATED 1, TEST 0, CONN 3 | 19 |
| ALR-0013P | Position switch | 4c; INSERT 0, ISOLATED 0, TEST 1, CONN 3 | 19 |
| ALR-0040P | Position switch | 4c; INSERT 0, ISOLATED 0, TEST 4, CONN 0 | 19 |
| ALR-0004P | Position switch | 4c; INSERT 0, ISOLATED 0, TEST 0, CONN 4 | 19 |
| AWR-1B | Lifter | 92 kg; D 887 mm, W 710 mm; applicable ACBs AR2, AR3, AR440SB | 18 |
| AWR-2B | Lifter | 110 kg; D 912 mm, W 1150 mm; applicable ACBs AR2, AR3, AR4, AR6 | 18 |
| ANU-1 | OCR checker | Checks long time-delay, short time-delay, instantaneous and ground fault trip functions (used for AGR-11B) | 36 |
| ANU-2 | OCR test interface unit | Converts current into voltage for on-site testing of AGR OCRs with a constant-current generator; also tests the reverse power trip | 36 |
| CW80-40LS | Current transformer for neutral line (separate type) | Rated primary current 200, 400, 800, 1250, 1600 A; rated secondary current 5 A | 37 |
| EC160-40LS | Current transformer for neutral line (separate type) | Rated primary current 1600, 2000, 2500, 3200, 4000, 5000, 6300 A; rated secondary current 5 A | 37 |
| FS-2 | Castell lock (key interlock) | ACBs can be supplied with a cylinder lock or type FS-2 Castell lock | 39 |
Over-current releases, communication modules, position switches and other accessories for TemPower PRO ACBs · 47 rows · Terasaki TemPower PRO catalogue 25-I58E, accessories (pp. 7 to 54)
| Model | Accessory | Printed details | Catalogue page |
|---|---|---|---|
| AOX-LI | Over-current release, Standard type | For general feeder circuit; set by dial operation | 22 |
| AOX-LSI | Over-current release, Standard type | For general feeder circuit; set by dial operation | 22 |
| AOX-LSIG | Over-current release, Standard type | For general feeder circuit; set by dial operation | 22 |
| AOX-LSIR | Over-current release, Standard type | For generator protection; set by dial operation | 22 |
| AOX-LSI+ | Over-current release, Smart type | For general feeder circuit; set by push-button operation; measurement of circuit information | 22 |
| AOX-LSIG+ | Over-current release, Smart type | For general feeder circuit; set by push-button operation; measurement of circuit information | 22 |
| APX-1R | Communication module | Modbus RTU; for smart type OCR | 7 |
| APX-1T | Communication module | Modbus TCP; for smart type OCR | 7 |
| TVPAA | Adaptor for remote display | Required between the remote display and the smart type OCR | 7 |
| AQR-1 | Capacitor trip device | Rated voltage 100-120V AC; with the continuously-rated shunt trip it trips the ACB for up to 30 s after a large voltage drop | 20 |
| AZX-1TH | Conductive adapter - horizontal extension adapter | For horizontal terminals and front connections | 53 |
| AZX-1TF | Conductive adapter - vertical extension adapter | For front connections | 53 |
| TTP00 | OCR checker | Field check of long time-delay, short time-delay, instantaneous, ground fault, reverse power trip and preferential trip alarm functions | 54 |
| ALX-212PB | Position switch (standard) | 5c; ISOLATED 2, TEST 1, CONN 2 | 16 |
| ALX-211PB | Position switch (standard) | 4c; ISOLATED 2, TEST 1, CONN 1 | 16 |
| ALX-210PB | Position switch (standard) | 3c; ISOLATED 2, TEST 1, CONN 0 | 16 |
| ALX-202PB | Position switch (standard) | 4c; ISOLATED 2, TEST 0, CONN 2 | 16 |
| ALX-201PB | Position switch (standard) | 3c; ISOLATED 2, TEST 0, CONN 1 | 16 |
| ALX-200PB | Position switch (standard) | 2c; ISOLATED 2, TEST 0, CONN 0 | 16 |
| ALX-112PB | Position switch (standard) | 4c; ISOLATED 1, TEST 1, CONN 2 | 16 |
| ALX-111PB | Position switch (standard) | 3c; ISOLATED 1, TEST 1, CONN 1 | 16 |
| ALX-110PB | Position switch (standard) | 2c; ISOLATED 1, TEST 1, CONN 0 | 16 |
| ALX-102PB | Position switch (standard) | 3c; ISOLATED 1, TEST 0, CONN 2 | 16 |
| ALX-101PB | Position switch (standard) | 2c; ISOLATED 1, TEST 0, CONN 1 | 16 |
| ALX-100PB | Position switch (standard) | 1c; ISOLATED 1, TEST 0, CONN 0 | 16 |
| ALX-012PB | Position switch (standard) | 3c; ISOLATED 0, TEST 1, CONN 2 | 16 |
| ALX-011PB | Position switch (standard) | 2c; ISOLATED 0, TEST 1, CONN 1 | 16 |
| ALX-010PB | Position switch (standard) | 1c; ISOLATED 0, TEST 1, CONN 0 | 16 |
| ALX-002PB | Position switch (standard) | 2c; ISOLATED 0, TEST 0, CONN 2 | 16 |
| ALX-001PB | Position switch (standard) | 1c; ISOLATED 0, TEST 0, CONN 1 | 16 |
| ALX-212PA | Position switch (for microload) | 5c; ISOLATED 2, TEST 1, CONN 2 | 16 |
| ALX-211PA | Position switch (for microload) | 4c; ISOLATED 2, TEST 1, CONN 1 | 16 |
| ALX-210PA | Position switch (for microload) | 3c; ISOLATED 2, TEST 1, CONN 0 | 16 |
| ALX-202PA | Position switch (for microload) | 4c; ISOLATED 2, TEST 0, CONN 2 | 16 |
| ALX-201PA | Position switch (for microload) | 3c; ISOLATED 2, TEST 0, CONN 1 | 16 |
| ALX-200PA | Position switch (for microload) | 2c; ISOLATED 2, TEST 0, CONN 0 | 16 |
| ALX-112PA | Position switch (for microload) | 4c; ISOLATED 1, TEST 1, CONN 2 | 16 |
| ALX-111PA | Position switch (for microload) | 3c; ISOLATED 1, TEST 1, CONN 1 | 16 |
| ALX-110PA | Position switch (for microload) | 2c; ISOLATED 1, TEST 1, CONN 0 | 16 |
| ALX-102PA | Position switch (for microload) | 3c; ISOLATED 1, TEST 0, CONN 2 | 16 |
| ALX-101PA | Position switch (for microload) | 2c; ISOLATED 1, TEST 0, CONN 1 | 16 |
| ALX-100PA | Position switch (for microload) | 1c; ISOLATED 1, TEST 0, CONN 0 | 16 |
| ALX-012PA | Position switch (for microload) | 3c; ISOLATED 0, TEST 1, CONN 2 | 16 |
| ALX-011PA | Position switch (for microload) | 2c; ISOLATED 0, TEST 1, CONN 1 | 16 |
| ALX-010PA | Position switch (for microload) | 1c; ISOLATED 0, TEST 1, CONN 0 | 16 |
| ALX-002PA | Position switch (for microload) | 2c; ISOLATED 0, TEST 0, CONN 2 | 16 |
| ALX-001PA | Position switch (for microload) | 1c; ISOLATED 0, TEST 0, CONN 1 | 16 |
Bus-coupled plug-in base for TemBreak PRO breakers in distribution boards · 14 rows · Terasaki’s TemPlug70 page, ratings and specifications table (TemPlug70 catalogue)
| Model | Poles | Applicable: Molded case circuit breakers | Applicable: Non-automatic trip breakers/ Switch disconnectors (3P) | Applicable: Circuit breakers with earth leakage alarm (3P) | Applicable: Earth leakage circuit breakers (3P) | Applicable: Circuit breakers with motor protection (3P) | Applicable: Earth leakage circuit breakers with motor protection (3P) |
|---|---|---|---|---|---|---|---|
| T2PG05LS | 2 | S50-SF, S125-SF (15-50A) | - | ZAS125-SF (15-50A) | ZS50-SF, ZS125-SF (15-50A) | - | ZS100-SM 3 (16-45A) |
| T2PG05LS | 3 | S50-SF, S125-SF (15-50A) | - | ZAS125-SF (15-50A) | ZS50-SF, ZS125-SF (15-50A) | - | ZS100-SM 3 (16-45A) |
| T2PG12LS | 2 | S125-SF (60-125A) | S125-SN | ZAS125-SF (60-125A) | ZS125-SF (60-125A) | - | ZS100-SM 3 (60-100A) |
| T2PG12LS | 3 | S125-SF (60-125A) | S125-SN | ZAS125-SF (60-125A) | ZS125-SF (60-125A) | - | ZS100-SM 3 (60-100A) |
| T2PG12S | 2 | S100-GF, S125-GF | - | ZAS50-GF, ZAS100-GF, ZAS125-GF | ZS100-GF, 3 ZS125-GF | - | - |
| T2PG12S | 3 | S100-GF, S125-GF | - | ZAS50-GF, ZAS100-GF, ZAS125-GF | ZS100-GF, 3 ZS125-GF | - | - |
| TPPG12S | 2 | PS125-NF, PS125-GF, PS50-PF, PS125-PF | - | - | - | - | - |
| TPPG12S | 3 | PS125-NF, PS125-GF, PS50-PF, PS125-PF, PS125-NE, PS125-GE, PS125-PE | PS125-NN | - | - | PS125-NM | - |
| T2PG25H | 3 | H100-NF, H125-NF, H225-NF | - | - | - | - | - |
| T2PG25LS | 3 | E250-SF, PS250-NF, PS250-GF, PS250-PF, PS250-NE, PS250-GE, PS250-PE | S250-SN, PS250-NN | ZAE250-SF, ZAS250-SF | ZE250-SF, ZS250-SF | S250-SM | ZS250-SM |
| T2PG25S | 3 | - | - | ZAS225-GF, ZAS250-GF | ZS225-GF, ZS250-GF | - | - |
| T2PG40S | 3 | E400-NF | - | ZAE400-NF, ZAS400-NF, ZAS400-GF | ZE400-NF, ZS400-NF, ZS400-GF | - | - |
| TPPG40S | 3 | PS400-CF, PS400-NF, PS400-GF, PS400-NE, PS400-GE, PS630-CF 500A, PS630-NF 500A, PS630-GF 500A, PS630-NN 500A | PS400-NN, PS630-NN 500A | - | - | - | - |
| T2PG63S | 3 | S630-CF, S630-NF, S630-NE | S630-GN | ZAS630-CF, ZAS630-NF | ZS630-CF, ZS630-NF | - | - |
A dash means no applicable breaker is printed for that base.
Auxiliary, alarm, trip, lock and residual-current add-ons for TD3 devices · 10 rows · Terasaki Electric (Europe) TD3 leaflet (2022), accessories
| Code / key | Accessory | Printed details |
|---|---|---|
| A | Auxiliary contact | 1NO, 1NC. 6A, 230V AC. Not suitable for TD3RCCB |
| B | Alarm contact | 1NO, 1NC. 6A, 230V AC. Not suitable for TD3RCCB |
| C | RCCB switch | Combined auxiliary contact (1NO, 1NC, 6A, 230V AC) + alarm contact (1NO, 1NC, 6A, 230V AC) |
| D | Shunt trip | RCCB switch (C) must be fitted before fitting the shunt trip to the TD3RCCB |
| E | Undervoltage trip | RCCB switch (C) must be fitted first on the TD3RCCB |
| F | Overvoltage trip | Un 230V AC; opens the circuit breaker if supply voltage exceeds 280V AC; RCCB switch (C) must be fitted first on the TD3RCCB |
| G | Padlock | Suitable for TD3 M06, M10, XA (open and closed) and for TD31P1M (open position only) |
| H | Residual current block | For TD3 M06 and M10 |
| I | Rotary handle | For TD3 ICP |
| TD3LOK | Padlock Device for TD3 | Listed as an accessory in the Pro-DB distribution board leaflet (WMED25) |
Letters A to I are the leaflet’s picture keys, not order codes; TD3LOK is a printed order code. Name the accessory and the TD3 device when you order.
FMST quotes Terasaki MCCB, ACB and DIN-rail accessories on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example AL and T2MC12) and FMST replies with the current rate.
TemBreak PRO Accessories (28 models), TemBreak PRO Motor Operators (16 models), TemPower2 ACB Accessories (52 models), TemPower PRO ACB Accessories (47 models), TemPlug70 (14 models) and TD3 Accessories (10 models): 6 families and 167 models, each row as Terasaki’s own catalogues and product pages print it.
Each accessory family with what the catalogues print it for (or, where they print nothing, the series its name gives): TemBreak PRO Accessories: fits TemBreak PRO Economical, TemBreak PRO Standard, TemBreak PRO Standard 50-100 kA, TemBreak PRO High-fault, TemBreak PRO Current limiting, TemBreak PRO Motor protection, TemBreak PRO Switch-disconnectors, TemBreak PRO Non-automatic trip breakers, TemBreak PRO with Earth Leakage Alarm, Single-phase 3-wire with Earth Leakage Alarm, Single-phase 3-wire Neutral Open-phase Protection, TemBreak PRO Earth Leakage Economical, TemBreak PRO Earth Leakage Standard, TemBreak PRO Earth Leakage High-fault, TemBreak PRO Earth Leakage for Motor Protection and Single-phase 3-wire Earth Leakage Circuit Breakers; TemBreak PRO Motor Operators: fits TemBreak PRO Economical, TemBreak PRO Standard, TemBreak PRO Standard 50-100 kA, TemBreak PRO High-fault, TemBreak PRO Current limiting, TemBreak PRO Motor protection, TemBreak PRO Switch-disconnectors, TemBreak PRO Non-automatic trip breakers, TemBreak PRO with Earth Leakage Alarm, Single-phase 3-wire with Earth Leakage Alarm, Single-phase 3-wire Neutral Open-phase Protection, TemBreak PRO Earth Leakage Economical, TemBreak PRO Earth Leakage Standard, TemBreak PRO Earth Leakage High-fault, TemBreak PRO Earth Leakage for Motor Protection and Single-phase 3-wire Earth Leakage Circuit Breakers; TemPower2 ACB Accessories: fits TemPower2; TemPower PRO ACB Accessories: fits TemPower PRO and TemPower PRO Switch Disconnectors; TemPlug70: fits TemBreak PRO Economical, TemBreak PRO Standard, TemBreak PRO Standard 50-100 kA, TemBreak PRO High-fault, TemBreak PRO Motor protection, TemBreak PRO Switch-disconnectors, TemBreak PRO with Earth Leakage Alarm, TemBreak PRO Earth Leakage Economical, TemBreak PRO Earth Leakage Standard, TemBreak PRO Earth Leakage High-fault and TemBreak PRO Earth Leakage for Motor Protection; TD3 Accessories: fits TD3 Miniature Circuit Breakers and TD3 RCCBs and RCBOs.
Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of Terasaki in Lahore, supplying genuine Terasaki MCCB, ACB and DIN-rail accessories to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.
WhatsApp the order codes from this page, or your load list, and FMST quotes genuine Terasaki. Electrical desk: 0306 4758850. All Terasaki categories: Terasaki circuit breakers.