Authorized Partner & Distributor
TEMBREAK PRO EUROPEAN SERIES · ECONOMICAL · STANDARD · HIGH-FAULT · CURRENT LIMITING

Terasaki TemBreak PRO European MCCB in Pakistan

FMST lists 4 families of Terasaki TemBreak PRO European-series MCCBs (TemBreak PRO European Economical, TemBreak PRO European Standard, TemBreak PRO European High-fault and TemBreak PRO European Current limiting) with 139 models exactly as Terasaki’s own catalogues and product pages print them. FMST is an Authorized Partner & Distributor of Terasaki in Lahore.

4
families
139
models as printed
15–3,200 A
rated current printed
16–200 kA
breaking capacity printed
Terasaki TemBreak PRO European Economical
TemBreak PRO European Economical
Terasaki TemBreak PRO European Standard
TemBreak PRO European Standard
Terasaki TemBreak PRO European High-fault
TemBreak PRO European High-fault
Terasaki TemBreak PRO European Current limiting
TemBreak PRO European Current limiting
Terasaki · TemBreak PRO European Series

Terasaki TemBreak PRO European Series, family by family.

Terasaki’s own photos, printed specifications and every order code. Tap a card for the full table.

TemBreak PRO European EconomicalTerasaki TemBreak PRO European Economical

Terasaki TemBreak PRO European Economical series MCCB

Moulded case circuit breaker, fixed or adjustable thermal trip

1P, 2P, 3P, 4P · 15–630 A · 16–25 kA

18 models8 order codes
Quote
TemBreak PRO European StandardTerasaki TemBreak PRO European Standard

Terasaki TemBreak PRO European Standard series MCCB

Moulded case circuit breaker, thermal or electronic (TPOT, TPOP, XOU, XOS OCR)

1P, 2P, 3P, 4P · 15–3,200 A · 25–100 kA

91 models34 order codes
Quote
TemBreak PRO European High-faultTerasaki TemBreak PRO European High-fault

Terasaki TemBreak PRO European High-fault series MCCB

Moulded case circuit breaker, high breaking capacity

3P, 4P · 20–800 A · 110–125 kA

20 models8 order codes
Quote
TemBreak PRO European Current limitingTerasaki TemBreak PRO European Current limiting

Terasaki TemBreak PRO European Current limiting series MCCB

Current-limiting moulded case circuit breaker

3P, 4P · 20–800 A · 200 kA

10 models5 order codes
Quote

Terasaki TemBreak PRO European Series at a glance.

All 4 families on this page, with the values Terasaki’s own catalogues and product pages print. Ranges are computed from plain printed numbers only; a dash means nothing is printed. WhatsApp 0306 4758850 to ask.

FamilyModelsPolesRated currentFramesBreaking capacityTrip unitSource
Terasaki TemBreak PRO European Economical series MCCB181P, 2P, 3P, 4P15–630 A160, 250, 400, 630 A16–25 kAFixed thermal or adjustable thermalEuropean series page
Terasaki TemBreak PRO European Standard series MCCB911P, 2P, 3P, 4P15–3,200 A160, 250, 400, 630, 800, 1,000, 1,250, 1,600, 2,000, 2,500, 3,200 A25–100 kA—European series page
Terasaki TemBreak PRO European High-fault series MCCB203P, 4P20–800 A125, 160, 250, 400, 630, 800 A110–125 kA—European series page
Terasaki TemBreak PRO European Current limiting series MCCB103P, 4P20–800 A125, 160, 250, 400, 800 A200 kA—European series page

Every order code, as printed.

The 139 rows of these families exactly as Terasaki’s own catalogues and product pages print them, column for column. Where a cell is misprinted, a short note under the table says so.

Terasaki TemBreak PRO European Economical series MCCB

Moulded case circuit breaker, fixed or adjustable thermal trip · 18 rows · Terasaki’s TemBreak PRO European series page, Economical series, ratings and specifications table (catalogue 23-I68EJ)

ModelFrame [A]PolesRated current [A]Rated breaking capacity [kA] Icu/Ics (AC415V)Outline dimensions [mm] (WxHxD)Weight [kg]Fixed thermalAdjustable thermalElectronic TPOTElectronic TPOPElectronic XOUElectronic XOS
E160-SF160116, 20, 25, 32, 40, 50, 63, 80, 100, 12525/13 (AC240V)25x130x680.3●-----
E160-SF160215, 20, 30, 40, 50, 60, 75, 100, 125, 16016/850x130x680.6●-----
E160-SF160316, 20, 25, 32, 40, 50, 63, 80, 100, 125, 16016/875x130x680.8●-----
E160-SF160416, 20, 25, 32, 40, 50, 63, 80, 100, 125, 16016/8100x130x681.0●-----
E160-SJ160325, 40, 63, 80, 100, 125, 16016/875x130x680.8-●----
E160-SJ160425, 40, 63, 80, 100, 125, 16016/8100x130x681.0-●----
E250-SCF2503125, 150, 175, 200, 225, 25016/8105x165x681.5●-----
E250-SCF2504125, 150, 175, 200, 225, 25016/8140x165x681.9●-----
E250-SCJ2503100, 125, 160, 200, 25016/8105x165x681.5-●----
E250-SCJ2504100, 125, 160, 200, 25016/8140x165x681.9-●----
E250-SF2503125, 150, 175, 200, 225, 25025/19105x165x681.5●-----
E250-SF2504125, 150, 175, 200, 225, 25025/19140x165x681.9●-----
E250-SJ2503125, 150, 175, 200, 22525/19105x165x681.5-●----
E250-SJ2504125, 150, 175, 200, 22525/19140x165x681.9-●----
P400E4003250, 40025/25140x260x1035.5-●----
P400E4004250, 40025/25180x260x1037.3-●----
P630E630363025/25140x260x1035.9-●----
P630E630463025/25180x260x1037.8-●----

The 1-pole E160-SF breaking capacity is printed at AC240V; the other rows at AC415V. In the trip-unit columns, ● means available and a dash not available.

Terasaki TemBreak PRO European Standard series MCCB

Moulded case circuit breaker, thermal or electronic (TPOT, TPOP, XOU, XOS OCR) · 91 rows · Terasaki’s TemBreak PRO European series page, Standard series, ratings and specifications table (catalogue 23-I68EJ)

ModelFrame [A]PolesRated current [A]Rated breaking capacity [kA] Icu/Ics (AC415V)Outline dimensions [mm] (WxHxD)Weight [kg]Fixed thermalAdjustable thermalElectronic TPOTElectronic TPOPElectronic XOUElectronic XOS
S160-NF160116, 20, 25, 32, 40, 50, 63, 80, 100, 125, 16025/19 (AC240V)35x165x680.5●-----
S160-SCF160215, 20, 30, 40, 50, 60, 75, 100, 125, 16025/1350x130x680.6●-----
S160-SCF160316, 20, 35, 32, 40, 50, 60, 80, 100, 125, 16025/1375x130x680.8●-----
S160-SCF160416, 20, 35, 32, 40, 50, 60, 80, 100, 125, 16025/13100x130x681.0●-----
S160-SCJ160325, 40, 63, 80, 100, 125, 16025/1375x130x680.8-●----
S160-SCJ160425, 40, 63, 80, 100, 125, 16025/13100x130x681.0-●----
S160-SF160316, 20, 35, 32, 40, 50, 60, 80, 100, 125, 16040/2075x130x680.8●-----
S160-SF160416, 20, 35, 32, 40, 50, 60, 80, 100, 125, 16040/20100x130x681.0●-----
S160-SJ160325, 40, 63, 80, 100, 125, 16040/2075x130x680.8-●----
S160-SJ160425, 40, 63, 80, 100, 125, 16040/20100x130x681.0-●----
P160F160320, 32, 50, 63, 100,125, 16036/3690x130x681.0-●----
P160F160420, 32, 50, 63, 100,125, 16036/36120x130x681.3-●----
P160F1603In=40, In=100, In=16036/3690x130x681.0--●●--
P160F1604In=40, In=100, In=16036/36120x130x681.3--●●--
P160N160320, 32, 50, 63, 100, 125, 16050/5090x130x681.0-●----
P160N160420, 32, 50, 63, 100, 125, 16050/50120x130x681.3-●----
P160N1603In=40, In=100, In=16050/5090x130x681.0--●●--
P160N1604In=40, In=100, In=16050/50120x130x681.3--●●--
P160H160320, 32, 50, 63, 100, 125, 16070/5090x130x681.0-●----
P160H160420, 32, 50, 63, 100, 125, 16070/50120x130x681.3-●----
P160H1603In=40, In=100, In=16070/5090x130x681.0--●●--
P160H1604In=40, In=100, In=16070/50120x130x681.3--●●--
P250F250320, 32, 50, 63, 100, 125, 16036/36105x165x681.5-●----
P250F250420, 32, 50, 63, 100, 125, 16036/36140x165x682.0-●----
P250F2503In=40, In=100, In=160, In=25036/36105x165x681.5--●●--
P250F2504In=40, In=100, In=160, In=25036/36140x165x682.0--●●--
P250N250320, 32, 50, 63, 100, 125, 16050/50105x165x681.5-●----
P250N250420, 32, 50, 63, 100, 125, 16050/50140x165x682.0-●----
P250N2503In=40, In=100, In=160, In=25050/50105x165x681.5--●●--
P250N2504In=40, In=100, In=160, In=25050/50140x165x682.0--●●--
P250H250320, 32, 50, 63, 100, 125, 16070/50105x165x681.5-●----
P250H250420, 32, 50, 63, 100, 125, 16070/50140x165x682.0-●----
P250H2503In=40, In=100, In=160, In=25070/50105x165x681.5--●●--
P250H2504In=40, In=100, In=160, In=25070/50140x165x682.0--●●--
P400F4003250, 40036/36140x260x1035.5-●----
P400F4004250, 40036/36185x260x1037.3-●----
P400F4003In=250, In=40036/36140x260x1035.7--●●--
P400F4004In=250, In=40036/36185x260x1037.5--●●--
P400N4003250, 40050/50140x260x1035.5-●----
P400N4004250, 40050/50185x260x1037.3-●----
P400N4003In=250, In=40050/50140x260x1035.7--●●--
P400N4004In=250, In=40050/50185x260x1037.5--●●--
P400H4003250, 40070/70140x260x1035.5-●----
P400H4004250, 40070/70185x260x1037.3-●----
P400H4003In=250, In=40070/70140x260x1035.7--●●--
P400H4004In=250, In=40070/70185x260x1037.5--●●--
P630F630363036/36140x260x1035.9-●----
P630F630463036/36185x260x1037.8-●----
P630F6303In=63036/36140x260x1036.0--●●--
P630F6304In=63036/36185x260x1038.0--●●--
P630N630363050/50140x260x1035.9-●----
P630N630463050/50185x260x1037.8-●----
P630N6303In=63050/50140x260x1036.0--●●--
P630N6304In=63050/50185x260x1038.0--●●--
P630H630363070/70140x260x1035.9-●----
P630H630463070/70185x260x1037.8-●----
P630H6303In=63070/70140x260x1036.0--●●--
P630H6304In=63070/70185x260x1038.0--●●--
S800-CJ8003630,80036/36210x273x1038.5-●----
S800-CJ8004630,80036/36280x273x10311.5-●----
S800-NJ8003630,80050/50210x273x1038.5-●----
S800-NJ8004630,80050/50280x273x10311.5-●----
S800-NE8003In=630, In=80050/50210x273x1039.1----●-
S800-NE8004In=630, In=80050/50280x273x10312.3----●-
S800-RJ8003630,80070/50210x273x1038.5-●----
S800-RJ8004630,80070/50280x273x10311.5-●----
S800-RE8003In=630, In=80070/50210x273x1039.1----●-
S800-RE8004In=630, In=80070/50280x273x10312.3----●-
S800-PJ8003630,800100/50210x273x1038.5-●----
S800-PJ8004630,800100/50280x273x10311.5-●----
S800-PE8003In=630, In=800100/50210x273x1039.1----●-
S800-PE8004In=630, In=800100/50280x273x10312.3----●-
S1000-SE10003In=100050/38210x273x10311.0----●-
S1000-SE10004In=100050/38280x273x10314.8----●-
S1000-NE10003In=100070/50210x273x10311.0----●-
S1000-NE10004In=100070/50280x273x10314.8----●-
S1250-SE12503In=800, In=125050/38210x370x12019.8----●-
S1250-SE12504In=800, In=125050/38280x370x12025.0----●-
S1250-NE12503In=800, In=125070/50210x370x12019.8----●-
S1250-NE12504In=800, In=125070/50280x370x12025.0----●-
S1250-GE12503In=800, In=125085/65210x370x12019.8----●-
S1250-GE12504In=800, In=125085/65280x370x12025.0----●-
S1600-SE16003In=160050/38210x370x14027.0----●-
S1600-SE16004In=160050/38280x370x14035.0----●-
S1600-NE16003In=160085/65210x370x14027.0----●-
S1600-NE16004In=160085/65280x370x14035.0----●-
XS2000NE20003In=200085/65320x450x18554.0-----●
XS2000NE20004In=200085/65429x450x18567.0-----●
XS2500NE25003In=250085/65320x450x18564.0-----●
XS2500NE25004In=250085/65429x450x18578.2-----●
XS3200NE32003In=320085/65320x450x18565.0-----●

S160-SCF and S160-SF print the rated currents 16, 20, 35, 32 … : 35 is as printed (sic), probably 25. The P250 thermal rows list currents only up to 160 A in the 250 A frame, as printed. The 1-pole rows print the breaking capacity at AC240V. Several types here carry the same designations as TemBreak 2 types (for example S800-NE, S1250-NE): name the series when you order. In the trip-unit columns, ● means available and a dash not available.

Terasaki TemBreak PRO European High-fault series MCCB

Moulded case circuit breaker, high breaking capacity · 20 rows · Terasaki’s TemBreak PRO European series page, High-fault series, ratings and specifications table (catalogue 23-I68EJ)

ModelFrame [A]PolesRated current [A]Rated breaking capacity [kA] Icu/Ics (AC415V)Outline dimensions [mm] (WxHxD)Weight [kg]Fixed thermalAdjustable thermalElectronic TPOTElectronic TPOPElectronic XOUElectronic XOS
H125-NJ125320, 32, 50, 63, 100, 125125/85105x165x1032.4-●----
H125-NJ125420, 32, 50, 63, 100, 125125/85140x165x1033.2-●----
H160-NJ1603160125/85105x165x1032.4-●----
H160-NJ1604160125/85140x165x1033.2-●----
H250-NJ2503160, 250125/85105x165x1032.4-●----
H250-NJ2504160, 250125/85140x165x1033.2-●----
H250-NE2503In=40, In=125, In=160, In=250125/85105x165x1032.5----●-
H250-NE2504In=40, In=125, In=160, In=250125/85140x165x1033.3----●-
P400S4003250, 400110/110140x260x1035.5-●----
P400S4004250, 400110/110185x260x1037.3-●----
P400S4003In=250, In=400110/110140x260x1035.7--●●--
P400S4004In=250, In=400110/110185x260x1037.5--●●--
H400-NE4003In=250, In=400125/85140x260x1407.1----●-
H400-NE4004In=250, In=400125/85185x260x1409.4----●-
P630S6303630110/110140x260x1035.9-●----
P630S6304630110/110185x260x1037.8-●----
P630S6303In=630110/110140x260x1036.0--●●--
P630S6304In=630110/110185x260x1038.0--●●--
H800-NE8003In=630, In=800125/94210x273x14014.8----●-
H800-NE8004In=630, In=800125/94280x273x14018.8----●-

Several types here carry the same designations as TemBreak 2 types (for example H250-NJ, H400-NE): name the series when you order. In the trip-unit columns, ● means available and a dash not available.

Terasaki TemBreak PRO European Current limiting series MCCB

Current-limiting moulded case circuit breaker · 10 rows · Terasaki’s TemBreak PRO European series page, Current limiting series, ratings and specifications table (catalogue 23-I68EJ)

ModelFrame [A]PolesRated current [A]Rated breaking capacity [kA] Icu/Ics (AC415V)Outline dimensions [mm] (WxHxD)Weight [kg]Fixed thermalAdjustable thermalElectronic TPOTElectronic TPOPElectronic XOUElectronic XOS
L125-NJ125320, 32, 50, 63, 100, 125200/150105x165x1032.4-●----
L125-NJ125420, 32, 50, 63, 100, 125200/150140x165x1033.2-●----
L160-NJ1603160200/150105x165x1032.4-●----
L160-NJ1604160200/150140x165x1033.2-●----
L250-NJ2503160,250200/150105x165x1032.4-●----
L250-NJ2504160,250200/150140x165x1033.2-●----
L400-NE4003In=250, In=400200/150140x260x1407.1----●-
L400-NE4004In=250, In=400200/150185x260x1409.4----●-
L800-NE8003In=630, In=800200/150210x273x14014.8----●-
L800-NE8004In=630, In=800200/150280x273x14018.8----●-

These types carry the same designations as TemBreak 2 Limiting types (for example L400-NE, L800-NE): name the series when you order. In the trip-unit columns, ● means available and a dash not available.

Compare all brands

The same products from every circuit breaker brand FMST supplies as an Authorized Partner & Distributor, on one page each.

Terasaki TemBreak PRO European Series: your questions.

What is the price of Terasaki TemBreak PRO European-series MCCBs in Pakistan?

FMST quotes Terasaki TemBreak PRO European-series MCCBs on request, because the rate depends on the model, rating and quantity. WhatsApp 0306 4758850 with the order code (for example E160-SF and S160-NF) and FMST replies with the current rate.

Which Terasaki TemBreak PRO European-series MCCBs does FMST supply?

TemBreak PRO European Economical (18 models), TemBreak PRO European Standard (91 models), TemBreak PRO European High-fault (20 models) and TemBreak PRO European Current limiting (10 models): 4 families and 139 models, each row as Terasaki’s own catalogues and product pages print it.

What is the difference between the Terasaki MCCB ranges?

As printed: TemBreak PRO European Economical: Moulded case circuit breaker, fixed or adjustable thermal trip, 15–630 A in 160, 250, 400, 630 A frames, 16–25 kA; TemBreak PRO European Standard: Moulded case circuit breaker, thermal or electronic (TPOT, TPOP, XOU, XOS OCR), 15–3,200 A in 160, 250, 400, 630, 800, 1,000, 1,250, 1,600, 2,000, 2,500, 3,200 A frames, 25–100 kA; TemBreak PRO European High-fault: Moulded case circuit breaker, high breaking capacity, 20–800 A in 125, 160, 250, 400, 630, 800 A frames, 110–125 kA; TemBreak PRO European Current limiting: Current-limiting moulded case circuit breaker, 20–800 A in 125, 160, 250, 400, 800 A frames, 200 kA. Rows that print the same code for 3 and 4 poles are separate rows in the tables below.

Is FMST an Authorized Partner & Distributor of Terasaki in Pakistan?

Yes. FMST (Finest Material Supplier & Traders) is an Authorized Partner & Distributor of Terasaki in Lahore, supplying genuine Terasaki TemBreak PRO European-series MCCBs to contractors, panel builders, developers and buyers across Pakistan. WhatsApp 0306 4758850 with your list.

Need Terasaki TemBreak PRO European Series? Send the codes.

WhatsApp the order codes from this page, or your load list, and FMST quotes genuine Terasaki. Electrical desk: 0306 4758850. All Terasaki categories: Terasaki circuit breakers.